Datalogic Gryphon I GBT4130 Manual de digitalização - Página 7

Procurar online ou descarregar pdf Manual de digitalização para Leitor de código de barras Datalogic Gryphon I GBT4130. Datalogic Gryphon I GBT4130 8 páginas. General purpose handheld linear imager barcode reader with bluetooth wireless technology

Addendum
Linking the Scanner to the Base Station
The handheld Reader should link automatically to the Base Station when placed in the cradle to charge. Follow the procedure below
if it is determined that the Reader and Base have not established a link connection. It is possible that another Bluetooth device has
or is interfering with the establishment of the link.
1. Scan the Unlink barcode below
the Reader will emit multiple tones and the Base Red/Green LED will blank
2. Press the trigger to wake the Reader and place it in the Base cradle
the scanner will emit three ascending tones and the Base Red/Green LED will flash multiple times then become solid
indicating that a link has been established – LED color is dependent upon the charging state
3. If the Reader fails to establish a link connection to the Base
Confirm that all physical connections are properly made
Look for possible sources of Bluetooth interference and power them off
Attempt the connection procedure again beginning with step1 above
Do not scan Unlink unless you have confirmed that the Reader and Base are not communicating.
The mandatory conditions for establishing a new linking between a Bluetooth handheld and a Bluetooth base is that the handheld is
unlinked and they share the same security configuration. A successful link is indicated by three ascending tones from the Reader. A
high-low-high-low tone indicates the link attempt was unsuccessful. A single green LED flash after this tone indicates no Base
Station was discovered. Two green LED flashes after this tone indicates that more than one Base Station was discovered and the
Reader did not link. Three LED flashes after this tone indicate a security error.
If you continue to have difficulty with setup, please contact PDS or Datalogic Tech Support for assistance.
There are additional reading parameters, performance and behavior settings that may be of benefit and relevant to your scanning
environment. If you will call PDS Tech Support they will be able to discuss your scanning environment and help you determine if
there are settings that may enhance the use of the Reader in your store environment.
Replacing the Battery
The Lithium-Ion Battery is considered to be field replaceable by Datalogic and they recommend annual replacement of rechargeable
battery packs to ensure maximum performance. They also provide a step by step replacement procedure in their Quick Reference
Guide. In addition, there is a maintenance video demonstrating battery replacement that can be linked to from their website. If you
feel that this is something that you would rather not undertake yourself, you may contact Datalogic for service options.
www.scanning.datalogic.com
Replacement Batteries and the Optional 12V AC adapter are available from PDS for $30 each
~ (tone pattern) # extended > # # # melodic descending ~
Page 7 of 8