Dust Free 04966MV Manual de instalação e operação - Página 5

Procurar online ou descarregar pdf Manual de instalação e operação para Filtro de ar Dust Free 04966MV. Dust Free 04966MV 8 páginas. Ultraviolet light systems

BIO-FIGHTER
®
NOMAD, NOMAD 2 INSTALLATION & OPERATION MANUAL
INSTALLING THE NOMAD 2
Perpendicular Mount (Fig.4)
Place the Nomad 2 at the desired installation
location/orientation and secure to duct with
the included 1" mounting screws.
Optional spacers are provided to help prevent
"sweating" where insulation is compacted.
When using spacers use the 1.5" mounting
screws included with the Nomad 2.
Lamp repositioning holes.
Fig. 4 Mount the Nomad to the duct using the 1" mounting
screws.
Insert Mount
If installing the Nomad 2 as an insert-mount:
1. Make two 3" diameter lamp holes in the
ductwork.
2. Install lamps as shown on page 5.
3. Remove the retaining screws and bottom
cover of the Nomad 2.
4. Insert the Nomad 2 lamps through the holes
and secure chassis to duct using the provided
1" mounting screws. Any of the holes in the
cover may be used for mounting.
WARNING
Mercury Hazard. Do Not Break.
Each UV-C lamp contains a small amount of Mercury.
May cause redness or irritation. Use proper disposal
techniques in case of breakage. See page 6.

INSTALLING THE LAMP

To maximize the efficiency and life of the UV-C
lamp, clean each lamp prior to installation.
Use isopropyl alcohol and cotton cloth to wipe
dust and fingerprints from the lamp.
Attach lamp to connector by inserting the front
of the lamp into the connector first then gently
snap the back of the lamp in place.
Fig. 5 Attach lamp to connector by inserting the front of the lamp
first then snapping the back of the lamp into place.
WARNING
UV-C Light Hazard.
UV-C light can cause temporary or permanent loss of
vision, and sunburn. Take precautions to protect eyes
and skin from direct exposure.
CAUTION
Clean lamp(s) prior to installation.
Failure to remove dirt and fingerprints from the
lamp(s) could shorten their lifespan.
5