Datalogic Heron D140 Referência rápida - Página 9

Procurar online ou descarregar pdf Referência rápida para Scanner Datalogic Heron D140. Datalogic Heron D140 20 páginas. Barcode scanner

BEEPER/LED
VIDEO
ILLUMINATOR
+VCC
This scanner input drives the decoding LED,
the Good Read Spot and the beeper in the
scanner. The LED and Good Read Spot turn
on when a positive current is applied to the
pin. The beeper sound is obtained pulsating
this current at a frequency of about 2 kHz.
The maximum voltage that can be applied to
this input is 5 Vdc.
This "open collector" scanner output is
electrically
supplies a series of pulses the length of
which are proportional to the width of the
elements within the barcode read. Video
polarity is programmable. By default a low
output level corresponds to a bar. The
frequency of the pulses depends on the
density of the code, the distance from code
and the programmed output scan frequency
(see the following figure Video and Scan
signals).
A positive voltage (5 Vdc) is applied to this
input by the decoder when the decoding logic
senses the trigger is pressed; this causes the
activation of the illuminator and CCD.
This input must be connected to the positive
pin of the supply voltage (5 Vdc ± 5%). When
the ILLUMINATOR pin is positive, all the
current necessary to power the scanner flows
through +VCC.
CODE
VIDEO
SCAN
identical
to the barcode.
Video and scan signals
It