2easy DMR11-S4 Manual de início rápido - Página 5
Procurar online ou descarregar pdf Manual de início rápido para Sistema de intercomunicação 2easy DMR11-S4. 2easy DMR11-S4 16 páginas.
1.4. Multi Door Station wiring
ON
1 2
3 4 5 6
Code=4, DIP-6=on
ON
1 2
3 4 5 6
Code=2, DIP-6=on
1
A
ID=00
1 2
3 4 5 6
ON
2
ID=01
1 2
3 4 5 6
ON
[1]: The first Door Station, the DIP bit-1 and bit-2 should be set to 00.
[2]: The 2nd Door Station, the DIP bit-1 and bit-2 should be set to 01.
[3]: The 3rd Door Station, the DIP bit-1 and bit-2 should be set to 10.
[4]: The 4th Door Station, the DIP bit-1 and bit-2 should be set to 11.
[5]: Power Supply(PS5), MUST be installed side by side with DPS unit.
[6]: Power Separator, MUST be installed side by side with the PS5 unit.
[7]: DPS-4(4 input Power Separator), can connect Max. 4 Door Stations.
[8]: Monitor, each one with a unique User Code, note that all the bit-6 of
the DIP should be set to
[9]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to
HI
except the last one which is at the end of the bus
line.
8
CALL
UNLOCK
TALK/MON
IN-USE
8
CALL
UNLOCK
TALK/MON
IN-USE
(on) in this case.(Max.32 Monitors)
1
C
ON
1 2
3 4 5 6
Code=3, DIP-6=on
ON
1 2
3 4 5 6
Code=1, DIP-6=on
7
6
DPS-4
DPS
A B C D
BUS
3
ID=10
1 2
3 4 5 6
ON
4
ID=11
1 2
3 4 5 6
ON
- 5 -
8
CALL
UNLOCK
TALK/MON
IN-USE
8
CALL
UNLOCK
TALK/MON
IN-USE
PS5
5
85~260VAC
When Monitor quantity < 20
Cable Usage
Twisted cable 2x0.75 mm
2
Twisted cable 2x1 mm
When Monitor quantity > 20
Cable Usage
2
Twisted cable 2x1 mm
2
Twisted cable 2x1.5 mm
9
HI
B
A
B
C
60
60
30
2
80
80
40
A
B
C
70
30
20
70
50
30