Datalogic S5N-MR-2-B01-PP Manual de instruções

Procurar online ou descarregar pdf Manual de instruções para Acessórios Datalogic S5N-MR-2-B01-PP. Datalogic S5N-MR-2-B01-PP 7 páginas.

Datalogic S5N-MR-2-B01-PP Manual de instruções
This product is covered by one or more of the following patents.
European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1.
Italian Patent IT 1,321,772.
S5N-Mx-...-PP/NN SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (S5N-Mx...A00/B01/C01/C10/C21/D00/E01/F01/T01)
The yellow LED ON indicates that the N.O. (normally open) output
status is closed.
STABILITY LED (S5N-Mx...B01/C01/C21/E01/F01)
The green LED ON indicates that the received signal has a reserve
greater than 30% compared to the output switching value.
POWER ON LED (S5N-Mx...G00)
The green LED indicates that the sensor is operating.
TRIMMER (S5N-Mx...B01/C01/C21/E01/F01/T01)
The trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270° by a mechanical stop.
Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through
a  18 mm hole, using the two CH.24 nuts enclosed (22 Nm maximum
tightening torque).
Wide range of accessories available: various orientable fixing brackets
ease the sensor positioning (please refer to the accessories listed in the
general catalogue).
The operating distance is measured from the front surface of the sensor
lens.
C models: To improve the detection, the
object has to be moved closer or further away
from the front surface of the sensor lens.
In case of lateral translation, the object must
move as indicated in the figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
S5N-Mx...G00
BROWN
1
BROWN
1
+
10 ... 30 Vdc
+
WHITE
2
WHITE
2
N.C. OUTPUT
4
BLACK
4
BLACK
N.O. OUTPUT
BLUE
3
BLUE
3
0 V
M12 CONNECTOR
2
1
3
4
AXIAL VERSION
L
4
4
X
2.5
TRIMMER
49
FIBRE OPTIC VERSION
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating temperature:
Storage temperature:
Dielectric strength:
Insulation resistance:
Operating distance (typical values):
10 ... 30 Vdc
TEST +
TEST -
Emission type:
0 V
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
AtEx 2014/34/EU
Setting of S5N-Mx...A00
Position the sensor and reflector on opposite sides.
Find the points where the yellow LED (OUT) is switched ON and OFF in both vertical and horizontal positions, and fix the sensor in the center
between these points.
Setting of S5N-Mx...B01/T01
Position the sensor and reflector on opposite sides.
DIMENSIONS
RADIAL VERSION
L
14.5
12
4
4
10
X
14.5
TRIMMER
M O D E L S
with trimmer
without trimmer
67
57
L
X
43
38
STABILITY LED
OUTPUT LED
61
72.5
14.5
12
10
4
6.2
=
50
TRIMMER
STABILITY LED
OUTPUT LED
54.5
TECHNICAL DATA
S5N-MA AXIAL VERSION
10 ... 30 Vdc (limit values)
2 Vpp max.
35 mA max.
N.O. and N.C.; PNP or NPN (short-circuit protection)
100 mA max.
2 V max.
0.5 ms (2 ms mod.F01/G00)
1 kHz (250 Hz mod.F01/G00)
OUTPUT LED (YELLOW) excluding mod.G00
STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01)
POWER ON LED (GREEN) (mod.G00)
sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01)
-25 ... 55 °C
-25 ... 70 °C
500 Vac / 1 min. between electronic parts and housing
>20 M / 500 Vdc, between electronic parts and housing
A00: 0.1...4 M on R2
B01: 0.1...3.5 m on R2
C01: 0...60 cm
C10: 0...10 CM
C21: 0...35 cm
D00: 0.5...10 cm
F01/G00: 0...25 m
E01: 30 mm with OF-42 / 100 mm with OF-43
T01: 0.1...1 m on R2
red (630 nm) (mod. D00/E01) / red (660 nm) (mod.B01/T01)
infrared (880 nm) (mod. A00/C01/C10/C21/G00)
according to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Nickel-plated brass
PMMA
IP67 Type 1 enclosure
2 m cable  4 mm / M12 - 4 pole connector
110 g. max. cable vers. / 60 g. max. connector vers.
II 3D EX tc IIIC IP67 T85°C
SETTING
Turn the sensitivity trimmer to the maximum position.
Moving the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
middle of the points defined. Optimum operation is obtained when the
14.5
green LED (mod.B01) is ON and the yellow LED is OFF.
B01 models: If necessary reduce sensitivity in order to detect very small
targets. In order to improve alignment, repeat the procedure detailed
above whilst progressively reducing the sensitivity.
T01 model: Turn the sensitivity trimmer counterclockwise
until the yellow LED turns ON (pos.A).
Turn slowly the trimmer again clockwise until the yellow
10
LED turns OFF (Operating condition, pos.B).
Setting of S5N-Mx...F01/G00/E01 with OF-43 (P/R fibre-optics)
M O D E L S
Position the sensors (fibre terminals) on opposite sides.
with trimmer
without trimmer
79
69
Turn the sensitivity trimmer to maximum: moving the sensor both vertically
L
X
43
38
LED STABILITY
and horizontally, determine the power on and off points of the yellow LED
LED DI USCITA
(OUT) and then mount the sensor in the middle of the points defined.
mm
Optimum operation is obtained when the green LED is ON and the yellow
LED is OFF (the output function and the relative LEDs are inverted in the
CABLE VERSION
E01 model with the OF-43 fibre).
10
If necessary, reduce sensitivity using the trimmer, in order to detect very
small targets. In order to improve alignment, repeat the procedure detailed
above whilst progressively reducing the sensitivity.
Setting of S5N-Mx...C01/C21/E01 with OF-42 (proximity fibre)
Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow
LED is OFF. Position the target to detect in front of the sensor or of the
STABILITY LED
fibre terminals. Turn the sensitivity trimmer clockwise until the yellow LED
OUTPUT LED
turns ON (Target detected state, pos.A). Remove the target, the yellow
LED turns OFF. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON (Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected.
Turn the trimmer to the intermediate position C, between the two positions
A and B. The green LED must be ON.
S5N-MR RADIAL VERSION
Setting of S5N-Mx...C10/D00
The operating distance range of these sensors is factory preset: please
consider this feature when positioning.
TEST FUNCTION (S5N-Mx...G00)
The TEST+ and TEST- inputs can be used to inhibit the emitter and verify
that the system is correctly operating.
The receiver output should switch when the test is activated while the
beam is uninterrupted.
The inputs activating voltage range is 10 ... 30 Vdc.
B01: 0.1...2 m on R2
C01: 0...35 cm
Datalogic S.r.l.
C10: 0...8 cm
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
D00: 0...8 cm
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
F01/G00: 0...20 m
T01: 0.1...1 m on R2
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
© 2007 - 2020 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS RESERVED.  Without
limiting the rights under copyright, no part of this documentation may be reproduced,
stored in or introduced into a retrieval system, or transmitted in any form or by any means,
or for any purpose, without the express written permission of Datalogic S.p.A. and/or its
affiliates. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in
many countries, including the U.S.A. and the E.U. All other trademarks and brands are
property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
A
C
B
MIN
MAX
For information about the disposal of Waste Electrical and
Electronic Equipment (WEEE), please refer to the website at
www.datalogic.com.
821005714 Rev. E