HOW TO PERFORM A PRELIMINARY
CHECKOUT
Before using your cassette drive unit to recall or store programs, you should
complete the preliminary checks - which are described below:
1.
Turn off the computer and connect the cassette unit through the cord to
the computer.
2.
Ensure that the cassette deck motor is off by checking that all of the
function keys are uP. If any are not, press the STOP button.
3.
Turn the computer on.
4.
Press the P LA Y button on the cassette unit Look to see that, as the button
is engaged, the READ/WRITE heads move towards the spindles and the
capstan comes into contact with the pinch roller (see Fig. 1). The take up
spindle should be moving smoothly in an anti-clockwise direction
5.
Now press the STOP button. The heads should move back and the spindle
stop.
6.
Press the REWIND button. The tape heads should remain in the inactive
position and the supply spindle should move rapidly clockwise.
7.
Press STOP again and then F. FWD. The tape heads should still remain
in the inactive position and the take-up spindle should move rapidly anti-
clQckwise.
8.
Press STOP once more and then GENTLY attempt to press REC. You
should feel strong mechanical resistance.
9.
If all has worked, your cassette has been properly checked and is ready go
to work.