For dir e ct in pu t s –
Use t he print er's + 5VDC and Ground t o supply
t he devices int erfacing t o t he GPI / O A input s
( as shown in t he sam ple circuit , right ) .
For isola t e d in pu t s –
To provide galvanic isolat ion for t he GPI / O A
input s, rem ove Jum per JMP 9 t hen supply an
ext ernal + 5VDC source volt age t o Pin 2, and
rem ove Jum per JMP 8 t hen supply an ext ernal
Ground t o Pin 1 ( as shown t his sam ple circuit ,
right ) .
Se ve n de dica t e d ou t pu t s are available for cont rol, warning, and error funct ions.
These open- collect or out put s have slew- lim it ed signal- edge rise and fall t im es t o
prevent cross t alk in t he cabling. Opt ional 10K ohm pull- up resist ors, t ied t o a
com m on point for use at eit her + 5 or + 24 VDC, are available via Jum per JMP 1.
N ot e : I f ext ernal pull- ups are used ( t hat is, wit hout Jum per JMP1 inst alled) ,
ensure t hat t he applied ext ernal volt age does not exceed + 30VDC.
The t able below det ails t he GPI / O A pin assignm ent s, set t ings and funct ions.
+5 VDC External Source
4
GPI/O A - J1
3
Start of Print
4
Slew Label
5
Toggle/Pause
6
Reprint
1
Ground
GPI/O A - J1
2
Vcc
3
Start of Print
4
Slew Label
5
Toggle/Pause
6
Reprint
Ground
1