Dux Endurance Six 26XN Manual do instalador - Página 5
Procurar online ou descarregar pdf Manual do instalador para Aquecedor de água Dux Endurance Six 26XN. Dux Endurance Six 26XN 14 páginas. Gas continuous flow water heater
Step 7
Gas Connection
• Fit a union to the water heater gas
inlet for easy connection and removal.
The thread diameter is R¾/20.
• Fit an AGA approved isolating gas
cock in the supply line adjacent to
the water heater gas connection.
• Ensure that the supply pipe and
the gas pressure regulator (LPG
or Natural Gas) has sufficient flow
capacity for this and other appliances
connected to the fitting line. Refer to
AG 601 for size of pipe.
• For LPG appliances, ensure that
gas cylinders are of sufficient size.
The water heater alone will require a
regulator of 4kg per hour capacity.
• Before connecting the appliance to
the gas service, purge any debris or
air from the gas service. Venting of
purged gas shall be an area free of
sources of ignition.
Close the isolating gas cock prior to
connection of the appliance.
• After connection, check all joints for
leaks with an approved leak tester.
Refer to AG 601 Installations
Standard for pipe sizing details. For
your assistance, we have included
the pipe sizing from AG 601 for
copper tube using Natural Gas in the
table in the margin.
Part No: IG090701
Version: B
Installer's Guide – Endurance six™
Installation Guide
Nominal Pipe
Straight Length
Size in mm
Of Pipe Metres
13
18
20
25
Note: The Endurance six requires 199 MJ/h for the
customer to get the full performance benefit.
Gas
Valve
Hourly Rate
in MJ/h
4
43.0
4
82.2
4
142.0
4
313.0
5