SIT Gas Control (operating on Natural Gas):
(i)
Light the burner. Remove temperature selector knob from the front.
(ii) Remove plastic cap covering the "NO PR" screw.
(iii) Check that exclusion screw "NO PR" is fully turned anti-clockwise
(iv) Rotate "PR ADJ" screw clockwise to increase, or anti-clockwise to decrease
pressure.
SIT Gas Control (operating on LPG):
(i)
Light the burner. Remove temperature selector knob from the front.
(ii) Remove plastic cap covering the "NO PR" screw.
(iii) Turn "PILOT ADJ" screw fully anti-clockwise.
(iv) Put pressure governor fully "out of service" by screwing the "NO PR" fully home in
a clockwise direction.
Note: Pressure adjustments at gas cylinder regulator should be conducted as required
to ensure correct supply pressure to water heater as per AG601.
(b) Ignition System (Spark Gap)
Check that the gap between the spark electrode and the pilot burner is 3 - 5mm and adjust
as necessary. Push the igniter button to test for a spark. (WARNING: Only test the spark
gap where there is no build up of gas.)
15