Dataradio Integra-TR Manual de instalação - Página 3

Procurar online ou descarregar pdf Manual de instalação para Modems de rádio Dataradio Integra-TR. Dataradio Integra-TR 9 páginas. Integrated wireless modem

GENERAL SPECIFICATIONS

These specifications are subject to change without notice.
GENERAL
Frequency
Channels
Channel Bandwidth
Operating Temperature
Supply voltage
Rx Current Drain at 13.3 VDC
Tx Current Drain at 13.3 VDC
Power Saving Mode Current Drain
1
Cold start
2
Warm Start Rx
3
Warm Start Tx
4
Tx Turnon Time
Rx/Tx Bandwidth, without tuning
*380 to 403 MHz frequency band is not FCC or IC type approved
+
Includes 102 cm power cable.
General RF Specifications (
RECEIVER
Sensitivity
Selectivity (25 kHz)
Selectivity (12.5 kHz)
Selectivity (6.25 kHz)
Intermodulation
Spurious Rejection
FM Hum and Noise
Conducted Spurious
TRANSMITTER
RF Power Output
Spurious and Harmonics
Frequency Tolerance (12.5 & 25 kHz)
Frequency Tolerance (6.25 kHz)
FM Hum and Noise
Tx Duty Cycle
1
Cold Start: time from DC power applied until unit is fully ready to receive or transmit data
2
Warm Start Rx: in power saving modes (sleep or suspend), wake-up time for full receiver recovery
3
Warm Start Tx: in power saving modes (sleep or suspend), wake-up time for full transceiver operation
4
Tx Turnon Time: typical Rx to Tx switching time for stable transmission
Part No. 001-4008-101
VHF
132-174 MHz
Multi-channel capability under system PLC control
Fuse protected against reverse voltage (internal surface mount 3A fuse: not field replaceable)
<220 mA (with a terminal connected to Integra-TR COM port)
45 to 60 msec (depending on radio model and temperature)
55 to 70 msec (depending on radio model and temperature)
18 MHz (132-150)
24 MHz (150-174)
RF Specifications are measured per TIA/EIA-603 with a psophometric baseband filter.)
VHF
>70 dB minimum
>60 dB minimum
>40 dB minimum
>70 dB minimum
>70 dB minimum
<-45 dB max (25 kHz)
VHF
<-73 dBc (-36 dBm)
2.5 PPM
1.0 PPM
<-45 dB (25 kHz)
50%, max. Tx time 30 seconds, extended Tx time with the cooling fan option
UHF
380-403 MHz*
403-512 MHz
6.25, 12.5 or 25 kHz models
-30q to + 60q C
10 - 16 VDC maximum (nominal 13.3)
<2.6 A
<20 mA
4 sec (typical)
15 ms (typical)
16 MHz except
20 MHz (450-470)
UHF
0.35 PV for 12 dB SINAD
<-45 dB max (25 kHz)
< -57 dBm
UHF
1 to 5 Watts, software adjustable
<-73 dBc (-36 dBm)
1.5 PPM
.5 PPM
<-45 dB (25 kHz)
1-12
900 MHz
928-960 MHz
32 MHz
900 MHz
> 65 dB minimum
>60 dB minimum
N/A
> 70 dB minimum
>70 dB minimum
<-40 dB max (25 kHz)
900 MHz
-57 dBc (-20 dBm)
1.5 PPM
N/A
<-40 dB (25 kHz)