Auscrown Y028NGWF-S Manual de instruções de instalação e funcionamento - Página 9
Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Queimador Auscrown Y028NGWF-S. Auscrown Y028NGWF-S 11 páginas. Duckbill stockpot burner with flame failure safety device
MAINTENANCE
Do not touch hot surfaces. Do not attempt any cleaning or maintenance within 30 minutes of the appliance
being used. Periodic maintenance should be performed at intervals not exceeding 6 months or when evident
such as with flame abnormality or burner discolouration. Flame abnormality or burner discolouration is
generally a sign of gas supply restriction or blocked burner ports.
The pilot provides a flame to light the main burner. If the pilot is blocked by debris, spider webs, etc., the
pilot flame may be too small resulting in erratic ignition of the main burner. If this occurs, it will be necessary
to clean the pilot with compressed air. It is recommended that an authorised person perform all maintenance.
If the appliance fails to operate normally, contact the place of purchase, or their authorised agent for advice
and service. DO NOT ATTEMPT REPAIRS YOURSELF.
It is also recommended that the hose assembly and regulator inlet fitting seals be checked for damage,
abrasion, cracking or displacement before each use. PVC hose assemblies may harden with age and should
be replaced if this occurs. If a replacement part or assembly is required please contact place of purchase or
authorized service agent for advice.
TROUBLESHOOTING . DO NOT MODIFY THIS APPLIANCE.
If the appliance cannot be adjusted to perform correctly contact after sales service contact
details this page.
Problem
Possible Cause
Main Gas Valve is not
turned on.
Air trapped in the gas
No Ignition
hose.
The safety valve is not
open.
Gas Leaking
Failure of the gas valve.
Incomplete
Injector is clogged.
Combustion
(Yellow Flame)
SPECIFICATIONS
Product Name
Model No.
Gas Type
Gas Pressure
Injector Size
Gas Consumption
Inlet Fitting
Heat Capacity
Dimensions
Pot Size (Min/Max)
Approval No.:
AC-R2-001
18 Jet Duckbill Burner Cooker
Y018LPWF-S
LP
2.75kPa
Ø0.58mm
1.34kg/hr
CGA-510 POL
with Soft Nose
73MJ/hr
W55cm x D56cm x H44.5-49.5cm
Ø44cm/Ø49cm
Solution
Turn off the gas valve once and then turn it on fully.
Repeat the ignition process until all air in the hose is
purged completely.
Follow the procedures from 1 to 6 in the section of "Ignite
the burner".
Contact your dealer for a service/repair.
DO NOT ATTEMPT TO REPAIR IT YOURSELF.
Clean the injector.
Y018NGWF-S
Natural
0.90kPa
Ø0.98mm
1.76m³/hr
½" BSPF
IAPMO Gas Mark GMK10005
28 Jet Duckbill Burner Cooker
Y028LPWF-S
LP
2.75kPa
Ø0.58mm
2.08kg/hr
CGA-510 POL
with Soft Nose
104MJ/hr
W68cm x D70cm x H52-57cm
Ø44cm/Ø61cm
Y028NGWF-S
Natural
0.90kPa
Ø0.98mm
2.74m³/hr
½" BSPF
Page 9