Datasensor S65-PA-5-Z Manual de instruções - Página 2
Procurar online ou descarregar pdf Manual de instruções para Acessórios Datasensor S65-PA-5-Z. Datasensor S65-PA-5-Z 3 páginas. Line sensor
SETTING OF THE 2 THRESHOLDS
The sensor setting is effected placing the object to detect directly in front of the sensor following the
procedure given below:
push-button pressed
LED on
- Obect detection at OFF/ON output switching
- Position the object inside the measurement area to define the measurement value (depending
on the operating mode used) corresponding to the OFF/ON switching of the digital output.
OUT
A
M1
M2
Dig1
- Press the SET push-button for at least 2s.
- The detected value for the first switching threshold appears (4Hz blinking until the SET push-
button is released).
- The value acquired can be changed using the +/- push-buttons.
OUT
A
M1
M2
Dig1
- The units change if these push-buttons are pressed repeatedly, the tens if kept pressed.
- Press the SET push-button again for at least 0.5 s. to end the detection phase of the first
switching threshold.
OUT
A
M1
M2
Dig1
- Obect detection at ON/OFF output switching
- Position the object inside the measurement area to define the measurement value (depending on
the operating mode used) corresponding to the ON/OFF switching of the digital output.
The detected value for the second switching threshold appears.
-
-
OUT
A
M1
M2
Dig1
- The present value appears (4Hz blinking).
- Press the SET push-button again for at least 0.5 s. to detect the second switching threshold.
OUT
A
M1
M2
Dig1
- The detected value for the second switching threshold appears.
- The value acquired can be changed using the +/- push-buttons.
OUT
A
M1
M2
Dig1
- The units change if these push-buttons are pressed repeatedly, the tens if kept pressed.
- Press the SET push-button again for at least 0.5 s. to end the detection phase.
OUT
A
M1
M2
Dig1
SWITCHING THRESHOLD ADJUSTMENT
OUT
A
M1
M2
Dig1
0
- Press one of the +/- push-buttons for at least 2 s.
- The "tH-1" message appears.
OUT
A
M1
M2
Dig1
t
- Switching threshold selection
- Use the +/- push-buttons to select the switching threshold.
OUT
A
M1
M2
Dig1
t
t
- Adjustment phase of the switching threshold
- Press the SET push-button for at least 0.5 s.
- The previously detected value appears.
- The value can be changed using the +/- push-buttons.
- The units change if these push-buttons are pressed repeatedly, the tens if kept pressed.
OUT
A
M1
M2
Dig1
0
- Press the SET push-button again for at least 0.5 s. to end the adjustment phase.
OUT
A
M1
M2
Dig1
0
SETTING OF THE PARAMETERS
OUT
A
M1
M2
Dig1
Press the SET push-button for at least 6s to enter into the parameter setting mode.
The "MEnu" message appears.
OUT
A
M1
M2
Dig1
M
- Pressing the + and –push-buttons the user can run up and down the menu, reading the
following messages.
push-button not pressed
LED off
Display
Keyboard
Dig2
Dig3
Dig4
+
SET
4
5
0
Dig2
Dig3
Dig4
+
SET
4
5
0
Dig2
Dig3
Dig4
+
SET
4
5
0
Dig2
Dig3
Dig4
+
SET
6
0
0
Dig2
Dig3
Dig4
+
SET
6
0
0
Dig2
Dig3
Dig4
+
SET
6
0
0
Dig2
Dig3
Dig4
+
SET
6
0
0
Display
Keyboard
Dig2
Dig3
Dig4
+
SET
4
5
0
Dig2
Dig3
Dig4
+
SET
H
-
1
Dig2
Dig3
Dig4
+
SET
H
-
1
H
-
2
Dig2
Dig3
Dig4
+
SET
6
0
0
Dig2
Dig3
Dig4
+
SET
4
5
0
Display
Keyboard
Dig2
Dig3
Dig4
+
SET
4
5
0
Dig2
Dig3
Dig4
+
SET
E
n
u
- Functioning mode selection
- At each pressure on the SET push-button the user can run through the options of the selected
level.
OUT
A
M1
-
- Delay setting
- At each pressure on the SET push-button the user can run through the options of the selected
level.
OUT
A
M1
-
-
- The setting of the delay value is in common to both outputs.
When the delay value set is different from zero, the outputs will remain active for a minimum
time equal to the number of milliseconds visualised on the display.
-
- Visualisation of the threshold 1 data
- Pressing the SET push-button the value of the threshold 1 appears.
OUT
A
M1
-
THRESHOLD
- Visualisation of the threshold 2 data
- Pressing the SET push-button the value of the threshold 2 appears.
-
OUT
A
M1
THRESHOLD
-
- Visualsation of the operating area status
- Pressing the SET push-button the operating area status. More precisely; if "FULL" the operating
area is complete, if "REDU" the acquired area is not complete, but presents some zones that do
not have to be detected .
OUT
A
M1
-
- Reset of the sensor default configuration
-
- Pressing the SET push-button (the "RESE" message blinks for 2s, 4Hz) the default configuration
is re-set and the user exits from the menu, returning to the normal mode. The default
configuration is: "beg object" operating mode, delay 0, Th1 switching threshold = 100, Th2 =
200.
OUT
A
M1
-
- Memorisation of the parameters set
- Pressing the SET push-button (the "SAVE" message blinks for 2s, 4Hz) all the modified values
are memorised and the user exits form the menu,returning to the normal mode.
OUT
A
M1
-
- Press one of the +/- push-buttons the user can return to the setting menu.
- Exit from the parameter setting menu
After 10s inactivity of the sensor push-buttons, the sensor returns to the normal operating mode
-
visualising the distance.
OUT
A
M1
-
- Operating area selection
- Press contemporarily the + and – push-buttons for at least 2s.
- The "W_Ar" message appears.
-
OUT
A
M1
- The operating area configuration is memorised when the push-buttons are released (the W_Ar
blinks for 2s, 4Hz) and the sensor returns to the normal mode.
M2
Dig1
Dig2
Dig3
Dig4
E
n
d
b
E
G
c
E
n
t
W
I
d
t
A
r
E
A
M2
Dig1
Dig2
Dig3
Dig4
d
-
0
0
d
-
0
5
d
-
1
0
d
-
2
0
d
-
3
0
d
-
4
0
M2
Dig1
Dig2
Dig3
Dig4
t
H
-
1
0
4
5
0
M2
Dig1
Dig2
Dig3
Dig4
t
H
-
2
6
0
0
M2
Dig1
Dig2
Dig3
Dig4
F
U
L
L
or
r
E
d
U
M2
Dig1
Dig2
Dig3
Dig4
r
E
S
E
r
E
S
E
M2
Dig1
Dig2
Dig3
Dig4
S
A
V
E
S
A
V
E
ADVANCED FUNCTIONS
Display
M2
Dig1
Dig2
Dig3
Dig4
0
4
5
0
M2
Dig1
Dig2
Dig3
Dig4
W
_
A
r
W
_
A
r
+
SET
-
+
SET
-
+
SET
-
+
SET
-
+
SET
-
+
SET
-
+
SET
-
Keyboard
+
SET
-
+
SET
-