Datavideo MCU-100 Manual do utilizador - Página 14
Procurar online ou descarregar pdf Manual do utilizador para Controlador Datavideo MCU-100. Datavideo MCU-100 18 páginas. Multi-camera controllers for panasonic cameras
Também para Datavideo MCU-100: Manual de início rápido (2 páginas)
How to save / load the camcorders' settings to / from a PC
It is possible to save the current settings on all four cameras from MCU-100 to a PC for later use. Also any
previously saved MCU-100 settings stored on a PC can also be loaded back to the MCU-100 unit. This can
be handy if multiple users have access to the equipment and you need a quick way to get back to your
preferred settings.
Use the following procedure to save the current camera settings set by the MCU-100 unit to a PC.
1. Power off the MCU-100 unit.
2. Connect the MCU-100 unit to PC using USB cable via the USB 2.0 (Mini B) interface.
3. Set the five switches
position.
4. Press and hold in both the CAM 1 & MU-1 buttons at same time and then power on the MCU-100
unit.
5. The seven segment LED Display will show "cU--", and the PC will detect the MCU-100 unit as an
external storage device named "MCU-100_MUx".
6. Open the "MCU-100_MUx" folder on the PC and copy "mu_param.bin" file to desired PC hard drive
location.
7. Once complete unplug the USB cable and reboot the the MCU-100 unit.
To load previously saved settings on a PC to MCU-100.
Repeat steps 1~5 of the above procedure and then continue with the following steps.
6. Open the "MCU-100_MUx" file folder on PC and delete the "mu_param.bin" file.
7. Copy the previously saved "mu_param.bin" file from the PC hard drive location to the "MCU-
100_MUx" folder.
Note: Do not worry if the previously saved xxxxxxxxx.bin file has been renamed on the PC. The
MCU-100 unit will automatically amend the file name back to "mu_param.bin" after a reboot.
8. Once the copy process is complete unplug the USB cable and reboot the MCU-100 unit.
on the MCU-100 unit to their middle