USER MANUAL

Adjust settings

Adjustments
Dutch/german/english
Cleaning time :
Pond pump off :
Pond pump on :
Error after Pond pump off :
Tekst Message :
Refill valve :
Time after waste cleaning :
Time after cleaning :
Waste cleaning Enable :
Waste cleaning when :
Waste cleaning duration
Forced cleaning on / off:
Forced cleaning Time:
Description
To select a language, change the value of
the desired language to 1.
ATTENTION !: do not enable more than 1
language.
Set the duration of the cleaning time.
Pond pump switches off after X time low
water level .(Dry running protection).
Pond pump may only be switched on again
after an X time.( Start stop protection).
Gives an error when the pump has been
Switched off for the SET time.
Sends an SMS when the filter:
The pond pump is not controlled for a set
time.
ATTENTION !: SMS and Refill valve cannot
be used at the same time.
Using the valve to refill water (1 = on 0 = off)
Time that the top-up valve is switched after a
waste cleaning has taken place.
Time that the refill valve is switched after a
cleaning has taken place.
Waste cleaning on or off (1 = on 0 = off)
Let the waste cleaning take place after X
number of clean cycle.
Set the duration of the cleaning time.
Forced cleaning on or off (1 = on 0 = off)
After x time without automatic cleaning.
4