CHECKING THE HORIZONTAL LINE
1.
Position the device about 5 m from a wall and switch on the cross laser.
Mark point B on the wall.
2.
Turn the laser cross approx. 2.5 m to the right and mark point C.
3.
Check whether the horizontal line from point C is level with point B to within ± 2 mm.

MAINTENANCE AND SERVICE

Do not attempt to open the device. To ensure product SAFETY and RELIABILITY, repairs,
maintenance and adjustment should be performed by authorized service centres.
Contact your dealer for more details.
Do not drop, knock or shake the laser level as this will affect precision.
Remove batteries when the device is not in use.
Keep the laser level clean at all times. Use a soft lint-free cloth for the body and lens tissue
for glass windows. Do not use abrasive cleaners or solvents.
Don't expose the laser level to high temperatures or humidity.
Do not store the laser level in the hot areas, hot temperatures can short the life of
electronic device, damage battery, and warp or melt certain plastics
Do not store the laser level in the cold areas. When the unit warms up to its normal
operating temperature, moisture can form inside where it may damage circuit board.
Avoid shock, vibrations and extreme heat.
Do not immerse the instrument in water.
Always slide the power switch to the OFF position when storing, transporting or moving
around the job site.
Calibration is recommended at least once a year or as needed.