 Insure the fire diffuser is in place over the fire pot and the drip tray is in the
proper position under the indirect cooking grill.
 Place the drain bucket on the retaining clip under the drain tube.
 Place both grills in their proper position and follow the operating instructions
listed below.
OPERATING INSTRUCTIONS
 During first firing turn switch on and set the temp to 400 degrees. The ignitor will
stay on until the cooker gets to 140 degrees. It will take several minutes to get
pellets to drop into the fire pot.
 Leave doors open during igniting. Close when you see flames from the fire pot.
 Manual lighting instructions (in the event there should be a failure with the auto
igniter.) Pour ½ cup pellets into the fire pot. Squirt approximately 2 tablespoons
of alcohol gel into the fire pot and ignite with a match. Never attempt to squirt
alcohol gel onto burning embers to further ignite. This has the potential of serious
injury. Let this burn for 4-5 minutes, turn on the switch and set the thermostat to
300 degrees.
 Your grill has an "LHt" (Low Heat Time) and an "HHt" (High Heat Time)
adjustment that allows you to make some adjustment to the ON time the auger
runs when above or below temp. This allows you to fine tune the operation of the
grill. These are set at a standard setting from the factory and we recommend
getting use to your grill before making adjustments. The unit comes preset at LHt
10 and HHt 100.
 Press and hold UP+DOWN for 5 seconds, display says "LHt". This is the "Low
Heat Time". This is the ON time when the temperature is above set point.
Release UP+DOWN to edit the value. Default is 3.5 sec which will register as 35
on the PG500.
 Press and hold UP+DOWN for 5 seconds, display says "LHt". CONTINUE
HOLDING UP+DOWN FOR ANOTHER 5 SECONDS, display says "HHt".
This is the "High Heat Time. This is the ON time when the temperature is below
set point. Release the UP+DOWN to edit the value. Default is 12 sec. which will
register as 120 on the PG500.