TROUBLESHOOTING
TROUBLE
Power LED not on
Distorted sound
No sound but amplifier is on
No sound from channels 3 and 4
Tones do not sound when triggered
LIKELY CAUSE
Power not reaching amplifier
Output is short circuit
Input is overloaded
Output is being over driven
Bass control is turned up
Volume controls down
Amplifier has overheated
DC fuse(s) blown
Priority function is being used
Tone generator volume too low
ES SERIES INSTALLATION AND OPERATION MANUAL
REMEDY
Check power switch is on
Check mains connection
Check mains fuse
Check speaker loads for shorts
Reduce input level at source
Reduce volume levels on front panel
Reduce Bass control level
Check volume controls
Check for obstructions above and below
Make sure the amplifier is well ventilated
Refer product to local Australian Monitor
dealer
Remove signal (disconnect input) from
channel 1 and 2
OR
Disable priority function using DIP switches
on the rear panel.
Increase the volume by turning the tone
volume clockwise
11