1. TECHNICAL DATA
As a stove of construction type 1, it is possible to
connect it to the flue pipe of an existing other stove
or another hearth for solid fuels, as long as the
chimney complies with DIN 4705, Part 3.
TECHNICAL DATA
Height
Width
Depth
Weight
Flue pipe outlet diameter
Nominal thermal output (EN 13240)
Maximum thermal capacity
Smallest heating capacity
2. IMPORTANT INFORMATION
The installation and operation information given here
is of general nature
. National and European stand-
ards, local and building regulations as well as fire
prevention laws must be observed during the op-
eration of the stove.
General safety instructions for
the operation of your stove
Thoroughly read the entire manual before start-
ing up your stove and observe the caution notices.
Your heating unit may not be moved without ap-
proved means of transport with sufficient load-bearing
capacity.
Your heating unit is not suitable to be used as a
stand or as a ladder.
Please keep in mind that
your stove's surface heats up
considerably
during
We therefore recommend wear-
ing a safety mitten when operat-
ing your stove.
Make your children aware of this particular dan-
ger and keep them at a distance from the heating unit
whenever it is in operation.
Only burn approved fuels and materials listed in
the chapter "Clean Burning".
The burning or placing of flammable or explosive
materials, such as empty spray cans and such like in-
to the firebox as well as the storage of such materials
in the immediate vicinity of your heating unit is strictly
forbidden due the danger of explosion.
Do not wear loose or flammable clothing when
adding fuel to the fire.
677 mm
400 mm
595 mm
85 kg
120 mm
6 kW
8 kW
3 kW
operation.
4
Room heating capacity (depending on
building insulation)
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the cal-
culation of the chimney measurements in accord-
ance with DIN 4705, Part 2
Fluegas mass flow
Fluegas temperature
Minimum feed pressure
Nominal thermal output
Placing non-heat-resistant objects on the heat-
ing unit or in the vicinity of the heating unit is forbid-
den.
Do not lay laundry onto the stove for drying.
Laundry hung up to dry must be kept at a safe dis-
tance from the stove because of the danger of fire.
The woodstove G1 is not suitable for long term
heating.
During the operation of your heating unit it is
forbidden to use flammable or explosive materials in
the same or an adjacent room to the one in which
your heating unit is located
The appliance must be operated with the stove
door closed.
The stove door and all fittings for adjusting the
stove must be closed, if the appliance is out of use.
Setting up your stove
Required safety distances
distances – see name plate - in Fig. 2)
with protection shield or convection cladding
a > 800 mm b > 700 mm c > 400 mm
without protection shield or convection cladding
a > 800 mm b > 300 mm c > 300 mm
(a – toward the front in the radiated area)
(b – to the side)
(c – to the back)
Make sure that the room in which the stove is set up
has at least one door or window into the outside or is
directly adjacent to such a room. Other fireplaces and
extractor hoods must not be operated in the same
.
room as the stove
english
48 – 124
m³
closed
5,2 g/s
closed
330 °C
closed
12 Pa
at 0.8 times
10 Pa
n. ther. outp.
.
(Minimum
: