TROUBLESHOOTING

PROBLEM
Low outgoing voltage.
Note: Only use RMS voltmeters to
measure the outgoing voltage.
Battery power is too low.
No output.

SPECIFICATIONS

RATED OUTPUT POWER
SURGE POWER
FREQUENCY
OUTPUT
AC REGULATION
AC VOLTAGE
WAVEFORM
USB PORT
RATED INPUT POWER
NO LOAD-
INPUT
DC VOLTAGE
EFFICIENCY (Typ.)
FUSE
BATTERY LOW ALARM
BATTERY LOW SHUTDOWN
OUTPUT OVERLOAD PROTECTION
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
OUTPUT SHORT
BATTERY POLARITY
CLASSIFICATION
DIMENSIONS
CAUSE
The power inverter is overloaded
Incoming voltage is below 10 volt. Ensure adequate incoming voltage of over 10
Poor condition of the battery.
Inadequate power supply or
inappropriate voltage drops.
The power inverter is not at
operating temperature.
Battery voltage below 10 Volt.
Power inverter has cut-off
automatically due to overheating.
The fuse has blown.
240VAC, 50Hz, 2.5A, 500VA (continuous), 600VA (10 minutes)
RECOMMENDATION
Reduce the outgoing output.
volt.
Replace the battery.
Check the condition of the battery clamps.
Switch the power inverter off and on again.
If necessary, repeat the process until the
attached appliance starts.
Charge or exchange the battery
Allow the power inverter to cool down. Ensure
there is enough air circulation.
In the event that the leads are incorrectly
attached and the unit fails to operate, it will
be because the fuses have blown. You will
need to take the unit to a certified licensed
electrician to have the fuses replaced. Under no
circumstance are unlicensed electrical persons
permitted to open the unit to replace fuses
or conduct other repairs. Check that the wires
are connected correctly when connecting the
power inverter (see diagram on Page 9).
1200VA
50Hz
± 10%
240V AC
Modified sine wave
5V, 500mA DC
12V DC , 56A
≤ 0.5A
12V DC
≥ 80%
35AMP X 2
10V DC ± 0.5V
9.5V DC ± 0.5V
≥ 720W
Shut off output voltage, re-power on to recover
15.5 ± 0.5V
>65°C ± 5°C
Auto. Shut-off
By fuse
Equipollently bonded inverter
220 x 155 x 65mm
11