BENDIX AD-9si Dados de serviço
Heater & Thermostat Replacement Kit
Heater
Screws
Governor
Screws
Governor
Governor Kit
Figure 7 – Bendix
AD-9si
®
TEMPORARY AIR DRYER BYPASS
To temporarily bypass the air dryer, follow these procedures
and be sure to adhere to the General Safety Guidelines
outlined elsewhere in this document.
Make sure that all residual pressure has been released.
Slowly loosen the fitting that connects the air compressor
discharge line to the air dryer inlet port (IN 1) thereby
allowing any pressure trapped in the air dryer purge
reservoir to escape to the atmosphere. Once the pressure
has escaped and air flow has ceased, remove the fitting
that connects the air compressor discharge line to the air
dryer inlet fitting. Remove the air dryer delivery port fitting
Desiccant Cartridge
Replacement Kit
Heater &
Thermostat
Gasket
O-ring
Washer
O-ring
O-ring
Air Dryer Serviceable Components
®
O-ring
Purge
Valve
Retaining
Ring
(OUT 21). Using any necessary fittings, install a Tee fitting
in the air dryer delivery port. To one side of the Tee fitting
install the line removed from the air dryer delivery port, to
the opposite side of the Tee fitting install the line removed
from the air dryer inlet port. This procedure will allow the
integral governor to continue to regulate the air brake
system pressure properly.
After testing the Tee fitting for any air leakage – by using
a soap solution after charging to system cut-out pressure
(a 1 inch bubble in 10 seconds is acceptable) – the vehicle
may be returned to temporary service.
Safety
Valve
Delivery Check Valve
Replacement Kit
Delivery
Check Valve
Small
Body
O-ring
Spring
Cover
Purge Valve
Assembly
11