dymax 110 Manual do utilizador - Página 12

Procurar online ou descarregar pdf Manual do utilizador para Unidade de controlo dymax 110. dymax 110 20 páginas. Spray valves

12
Dymax Model 110 & 210 Spray Valves User Guide

Maintenance and Cleaning

General Valve Maintenance

Lubricate the Packing (E) on the valve every 200 hours by placing a few drops of mineral
oil or other light oil inside the Packing Nut (F).
The Packing Nut (F) will require occasional tightening as wear occurs in order to prevent
leaks through the Packing (E).

Routing Cleaning and Disassembly

Cleaning and rebuilding the valve will be required from time-to-time. A spare parts kit is
available with all the normal wear parts included. Refer to Figure 1 for part reference
designation.
1.
Begin disassembly by removing air and fluid pressure from the valve.
2.
Remove all pneumatic tubing and fluid delivery fittings, hoses, etc. from the valve.
3.
Loosen the Packing Nut (F) by using the tip of a 3/32" Allen key.
4.
Remove the two Machine Screws (Q) located on the same corners as the Standoffs
(G) with a 3/32" Allen key.
NOTE:
During removal, the valve's Spring (T) will force the air section away from
the fluid section.
5.
Pull the Air Section (M, I) away from the Fluid Section (D).
6.
Clean off the tip of the stainless steel Needle (C).
7.
Unthread and remove the Packing Nut (F) and Packing (E) from the fluid section (D)
of the valve.
8.
Using soft tip pliers unthread and remove the two Standoffs (G) from the fluid
section (D).
9.
Unthread and remove the Collar Ring (R) followed by the Air Cap (A).