Model 400 Dispensing Valve User Guide
5
General Safety Considerations
All users of Dymax fluid dispensing equipment should read and understand the user
guide before assembling and using the equipment.
To learn about the safe handling and use of dispensing fluids, obtain and read the SDS
for each fluid before using it. Dymax includes an SDS with each adhesive sold. SDS for
Dymax products can be requested through the Dymax website.
Specific Safety Considerations
Using Safe Operating Pressures
Pressurizing the components in the dispensing system beyond the maximum
recommended pressure can result in the rupturing of components and serious personal
injury. To minimize the risk of rupturing components and injury, do not exceed the
maximum operating pressure of the components in your fluid dispensing system (see
system specifications on page 13).
Preventing Injection Injury
Discharging fluids or compressed air with a dispensing tip against your skin can cause
very serious injection injury. To minimize the risk of injection injury, do not place the
dispensing tip in contact with your skin.
Product Overview
Description of the Model 400 Dispensing Valve
The Model 400 handheld, pneumatic needle valve is designed to deliver precise volumes
of low- to medium-viscosity fluids. Air pressure through the valve retracts the needle
assembly from the seat allowing fluid to flow from the valve fluid inlet to the dispensing
tip. When the air pressure is eliminated, the spring to returns the needle back to its
position, closing the fluid path and ending the dispense cycle. The valve also features a
flow adjustment knob which allows for fine-tuning of the dispense volume, ensuring
precise and consistent deposits. The Model 400 is ideally suited for a wide range of
applications including dispensing cyanoacrylates, inks, and UV light-curable adhesives.