HHO Plus CCPWM60A Manual de instalação - Página 9
Procurar online ou descarregar pdf Manual de instalação para Acessórios para automóveis HHO Plus CCPWM60A. HHO Plus CCPWM60A 12 páginas. Hho hydrogen on demand dual fuel generator systems
Também para HHO Plus CCPWM60A: Manual de instalação (11 páginas), Manual de instalação (10 páginas), Manual de instalação (10 páginas)
CCPWM60A – Installation Manual
9
Setting the operating values
The CCPWM60A is designed for making the automatic power supply of the HHO System without the need for
relays or picking up the signal from the alternator/ignition key, making the system safer to use and easier to
install. In general the new CCPWM60A will work based on the voltage of the car/truck:
Cars – 12V System
- Engine is stopped – voltage in car/truck is below 12,8V – CCPWM is not working;
- Engine is working – voltage in car/truck is above 12,8V – CCPWM is working;
For security reasons (ex: charging the battery) above 15V the CCPWM will not work and a blue light will
appear.
Cars – 24V System
- Engine is stopped – voltage in car/truck is below 25V – CCPWM is not working;
- Engine is working – voltage in car/truck is above 25V – CCPWM is working;
For security reasons (ex: charging the battery) above 29V the CCPWM will not work and a blue light will
appear.
The range of the operating voltage (12,8V/15V; 25V/29V) can be edited. If you press the right button (Config)
you will enter the configuration display where you can change the operating values of the CCPWM:
The CCPWM will only work when the real car voltage value is between the minimum and the maximum
working voltage value. For example if we work with the values displayed above the result will be:
Car voltage 13,4V ---------> CCPWM will work
Car voltage 14,6 V --------> CCPWM will not work
HHO Plus, Alternative Energies, Lta – Travessa das Serras 33, Vieira de Leiria, Portugal – Tel. 00351244697116 – Email: [email protected]