5Gstore EZ-62B Manual de configuração - Página 5

Procurar online ou descarregar pdf Manual de configuração para Interruptor 5Gstore EZ-62B. 5Gstore EZ-62B 15 páginas. Single outlet remote power switch

3. Settings
a. Outlet mode : Select between Auto Reset OR Manual Control
i. Auto Reset : The EZ-62B will Ping a specific address or the default website
addresses and when pings fail, power to the outlet will be reset
ii. Manual Control : User must access the Mobile App or Cloud website to
manually reset or power outlet ON/OFF
b. Ping Delay : This is the
time the EZ-62B will
wait after a Reset,
before it starts the ping
tests. This gives your
equipment enough time
to reboot. Default is 0
c. Power On Delay : This is
the time the EZ-62B will
take after a reset is
triggered, before the
outlet is powered back
on. Default is 3 seconds
d. No. of Resets : This is
the number of times the
outlet will automatically
reset when a time out is
detected. Configurable
from 1x-10x or infinite ∞
i. Example with 5x : If connectivity is not restored after the 5
will stop resetting after this 5
connection is restored. Default is 1x.
e. Reset Only - This disables the Turn OFF function. It is
recommended that when the EZ-62B is powering your modem or
router.
f. Ping Interval - Set the interval after a successful ping (i.e. how
frequently the EZ-62B is checking for a reply from the IP
Address(es) in use.
th
attempt. The EZ-62B will sit idle until the
th
reset, the outlet