Setting up the System

To get the 3G-SDI Camera Interface Board running, please follow the instructions below:
1. Connect the camera to the camera interface board connector (J1) using a KEL30 multi-way
cable (connector type: KEL USL00-30L). (If you have purchased a pre-assembled camera
module, e.g. AS-CIB-3GSDI-002-10LHD-A, this cable will be already be connected).
2. Connect the camera interface board I/O connector (J2) to the Harrier Evaluation board I/O
connector (J102) using the 4-way cable.
3. Connect the camera interface board PWR/CTRL connector (J3) to the Harrier Evaluation
Board PWR/CTRL connector using the 9-way cable; if you intend to use RS-232 connect the
cable to J103, for RS-485 connect the cable to J203.
For TTL communications either Harrier Evaluation Board socket (J103/J203) will work.
4. If you want to see the camera output on analog (720p50 & 720p60 modes only), connect the
J301 (Analog) BNC socket on the Harrier Evaluation Board to a monitor that can display
analog video using a suitable BNC cable/adapter.
5. If you want to see the 3G-SDI/HD-SDI camera output, connect the H.FL micro coaxial cable
to the J5 (SDI video) socket. Connect the other end of the H.FL micro coaxial cable to the
BNC adapter and use a 75 Ohm 3G-SDI/HD-SDI digital video quality BNC cable to connect
the adapter to a 3G-SDI/HD-SDI capable monitor/display.
6. If you want to use serial communications with the camera, use the mini USB–USB Type-A
cable to connect the mini USB socket on the Harrier Evaluation Board to a PC. The USB
PWR LED should light up indicating a live connection to the PC. Three serial interfaces will
appear as COM ports on the PC and be accessible to PC software.
7. Set/check the interface board DIP switch settings, e.g. SW1(1-4) OFF (no mode change on
power up), SW2 (1,2) OFF (RS232 serial communications), SW3 OFF (HD-VLC mode off).
8. Connect the power supply barrel connector to the Harrier Evaluation Board power input
connector (J306).
9. Set the Harrier Evaluation Board power switch (SW302) to OFF (left viewed from above).
10. Plug in the power supply and switch ON the Harrier Evaluation Board power switch (SW302).
The PWR ON should light up.
11. The camera will make audible mechanical noises as it goes through its power up sequence
and after a short time the video outputs will be working.
Note: if the DIP switches have been used to set the camera mode, and the mode last used
was different to the DIP switch setting, it will take a few additional seconds for the camera
interface board to detect this, change the camera mode and re-start the camera.
12. If an analog monitor is connected to the Harrier Evaluation board, and the camera mode is
set to 720p50/720p60, you will see the camera output on the analog monitor.
13. If the 3G-SDI/HD-SDI output is connected you will see the camera output on the 3G-SDI/HD-
SDI monitor/display.
September 2020