Great Circle GUT052 Manual do operador - Página 3

Procurar online ou descarregar pdf Manual do operador para Equipamento de controlo de insectos Great Circle GUT052. Great Circle GUT052 5 páginas. 3gal./12l fogger

4.7 Power off: Raise the spray nozzle higher than chemical tank, turn OFF power switch, keeping
2-3 seconds. The purpose is to let the remaining liquid in the pipe reflux into the tank, to
avoid the chemicals back up into the pipe and cause the motor moisture damage. Lastly turn
off the adjusting nut, to prevent the chemical outflow when adding liquid next time.
4.8 During the sprayer working, the high-speed gas flow will cause the gun and pipe heating, it
is a normal phenomenon.
5. Use Direction
5.1 The supply voltage should match the machine's requirements.
5.2 Do not make the power wire knotted and pull off forced; Prevent breakage of wire core and
circuit broken; Avoid the sharp objects to scratch the cable insulation layer and cause leakage.
5.3 Do not make the pipe folded and extruded, avoid the metal or other sharp objects puncture
the pipe.
5.4 Do not turn on and off power switch frequently, avoid damage the switch and motor. When
there is abnormal sound or small during working, shut down immediately, cut off the power,
and contact professional personnel to repair. If cannot resolve the problem locally, please
contact our company directly (1-866-493-0524), non-professionals is strictly prohibited
disassemble.
5.5 If not using for long time under the high humidity environment or in hot and rainy season, it
should always turn on for warm-up to eliminate humidity, prevent internal corrosion
damage.
5.6 If not using for long time, please keep in dry and cool place, do not let children play with the
machine, to avoid danger.
5.7 Keep the machine dry, wet hands are prohibited to operate the power switch, to avoid
electric shock.
5.8 When the machine is placed to add liquid chemical, avoid dumping, particular attention
during transportation.
5.9 After spraying the chemicals, please clean the machine with water. If spraying the
herbicide, please add detergent to clean completely. When finish spraying, the sprayer
should be clean and keep in a cool dry place to prevent direct sunshine and accelerated
plastic aging.

6. Technical Specification

Item No.
Tank Capacity
Net Weight
Rated Voltage
Motor Power
Particle Size
Max Flow Rate
GUT052
12L
3.5kg
230V/50Hz
1.4kw
0-50μm (Adjustable)
750 ML /min
2