5.1 Before First Use / Preparation
1. Immediately after unpacking, examine the unit for signs of transit damage and if found contact the
shipping company.
2. Establish the oil level in the oil reservoir (2). Depending on the shipping method used, the
reservoir may either be supplied full or empty. If the reservoir is empty, it must be correctly filled
before use (See section 5.2). If the reservoir was supplied full of oil, no further action is required.
IMPORTANT:
Running the pump without oil will result in damage.
5.2 Filling the Reservoir with Oil
IMPORTANT:
The AHP- BTU air driven hydraulic pumps use ISO46 Grade Hydraulic Oil.
Stand the Pump on a firm, level surface.
Remove the filler cap (3) from the filler breather.
Fill the reservoir with clean, high-quality ISO46 hydraulic oil via the opening at the top of the
reservoir.
Replace the filler cap (3).
IMPORTANT:
Only add oil to the reservoir when the attached tool is fully retracted. Failure to do so may
result in the system containing more oil than the reservoir can hold.
5.3 Hydraulic Connections
ALWAYS use Hi-Force XHC hoses to make connections.
Connection to the hydraulic pump must ALWAYS be made to the male coupler on the
tensioner/Hydraulic Nut.
Operating Instruction Manual:
OM-AHP-BTU-01

5.0 Installation / Setup

9
Serial Numbers:
FROM BQ 9522