Hi-Force HP227 Manual de Instruções - Página 6

Procurar online ou descarregar pdf Manual de Instruções para Bomba de água Hi-Force HP227. Hi-Force HP227 13 páginas. Manually operated hydraulic pump - steel
Também para Hi-Force HP227: Manual de instruções (6 páginas)

Hi-Force HP227 Manual de Instruções
Hi-Force declares that this product has been tested and complies with the standards and
declarations as set out in the Declaration of Incorporation/Conformity (DoI/DoC). The DoI/DoC is
included as Annex A to this instruction document and is supplied with all shipments of this
Hi-Force tools will use 1 of 2 grades of oil, dependant on the tool. The tools are designed to operate at
temperatures between -20°C and 80°C. Details of the oil used in this product can be found in, Section 6.2
ISO Hydraulic Oil Grade
ISO15
ISO46
Model
Valve
Number
Type
HP110
2-way
HP227
2-way
HP257
2-way
HP227FP*
2-way
HP227FPC**
2-way
*HP227FP comes with a foot operated handle.
**HP227FPC Comes with a foot operated handle, pressure gauge, gauge mounting block and 3 meter
hoses with male coupler.

3.0 Declaration of Incorporation / Conformity

4.0 Oil Specification
4.1 HP-Steel Specifications
Refer to the nameplate on the pump for identification.
Displacement per
stroke (cm3)
st
1
stage
Single stage pumps for single acting cylinders and tools.
2.9
Two stage pumps for single acting cylinders and tools.
12.9
12.9
12.9
12.9
Operating Instruction Manual:
OM-HP-STEEL-01
product.
Temperature Range: Degrees Celcius (°C)
From:
-23
-2
Usable
Oil
Capacity
nd
2
(litres)
stage
-
1.0
2.3
2.3
2.3
4.1
2.3
2.3
2.3
4.1
6
Serial Numbers:
From: DF6685
To:
44
73
Handle
Weight
Effort
(kg)
(kg)
45
5.6
38
10.5
38
15.2
38
10.5
38
15.2