If you find any damage due to shipping when unpacking the machine, contact your dealer
MILLIVOLT SYSTEM
Models MHGSQ35N, MHGSQ35P are intended to be a non-portable water heater for use with high pressure
washing equipment. There is no electrical connection to the pressure washer. The power for the gas control is
supplied entirely by the 750 millivolt power generator or thermopile. Power is generated when the pilot burner is
lit and will stop if the flame goes out.
GAS SUPPLY
For stationary installations, have the gas piping installed by a licensed gas fitter. This must be done in
accordance with the gas codes B149.1 for natural gas and B149.2 for propane gas.
FOR MHGSQ35P – PROPANE
For machines with portable LPG tanks with vapour withdrawal, connect the supply hose and regulator into the
POL fitting in the valve on the supply tank. Remember that this fitting has a left hand thread. Open the tank valve
and check for leaks in the propane connections with a soap solution. Depress the pilot valve for approximately a
minute to purge the lines of air. Wait 5 minutes to allow any escaped propane to dissipate before lighting the pilot.
WARNING - Do not use forklift tanks for this application - LPG ONLY
CAUTION - Propane gas in heavier than air and can collect in low hollow areas in an explosive mixture.
Ensure that the areas where you operate this machine are open to breezes, etc.
PROTECT FROM FREEZING
When transporting or storing your module at temperatures below freezing, make sure that the unit has been
properly winterized. (See Winterizing Your Pressure Washer). Even an overnight frost can split a coil or crack a
pump.
NOTE: - Models MHGSQ35N, MHGSQ35P, MHGSQ35NEI, MHGSQ35PEI are suitable for connection
to "A" venting when fitted with a draft hood.
Models MHGE500SQ, MHG500PSQ are sutable for connection to "B" venting when fitted with
a draft hood.
SETTING UP