Hi-Force HPP21012 Manual de Instruções - Página 8
Procurar online ou descarregar pdf Manual de Instruções para Bomba de água Hi-Force HPP21012. Hi-Force HPP21012 16 páginas. Petrol driven hydraulic pumps
5.1 Before First Use
1. Immediately after unpacking, examine the pump for signs of transit damage and if found contact the
shipping company.
2. Remove the temporary transit fitting / plate which is fitted in the position of the oil filler breather cap
(8) and fit the oil filler breather cap which is packed separately.
3. Establish the oil level in the oil reservoir using the level gauges (2). Depending on the shipping
method used, the reservoir may either be supplied full or empty. If the reservoir is empty, it must be
correctly filled before use (See section 5.4). If the pump was supplied full of oil, no further action is
required.
IMPORTANT:
CAUTION:
Ensure the oil level does not fall below the minimum level as shown by the lower
indicator (2).
4. Remove the steel or plastic hexagon headed plugs and make hydraulic connections to the service
ports (3). These ports have a 3/8" NPT female thread and the corresponding male connections
should be wrapped with PTFE tape or other suitable sealant.
NOTE: On a pump equipped with a 3-way valve the service port is the one on the right-hand side,
when viewed from the front. (See figure 4.1).
5. Ensure the lever of the hydraulic directional control valve (4) is set to the neutral position: This is fully
anti-clockwise for models with a 2-way valve, or the central position for models with a 3-way or
4-way valve.
NOTE: Where valves are remotely mounted, make sure they are adjusted such that pressure will not
build up during the starting operation. See section 8 for applicable models.
CAUTION:
Running the pump with the motor turning in the incorrect direction may damage the low-
pressure pump unit.
6. Check engine oil level by means of the dipstick located under the engine oil filler cap (11). Top up
as necessary.
7. Fill fuel tank with unleaded petrol (gasoline) via filler cap (10).
5.0 Installation/Setup
Running the pump without oil will result in damage.
Operating Instruction Manual:
OM-HPP-01
8
From Serial Number:
ALL