Hi-Force ALUMINIUM HP252 Manual de instruções
Model Series: HP110, HP227-257, HP211-252D, HPX1500-2800
Always operate the system under no load
condition prior to the actual lift to ensure that no
air is trapped in the hydraulic circuit.
Do not drop or place heavy objects on a
hydraulic hose as this will cause internal
damage to the hose which could result in
rupture when the hose is pressurized and could
result in serious damage to components, and
possible serious personal injury to operating
personnel.
3.0 General Information:
HP110 – Single Speed Manual Operation Steel
Construction Pump –Displacement: 2.9 cm
stroke- 700 bar maximum working pressure.
HP227, HP257 – Two Speed Manual Operation
Steel Construction Pump – Displacement: 1
Stage 12.9 cm
2
Stage 2.3 cm
3 :
nd
maximum working pressure.
HP245, HP245D – Two Speed Manual Operation
Steel Construction Pump – Displacement: 1
Stage 113 cm
2
Stage 4 cm
3 :
nd
maximum working pressure.
HP211 – Two Speed Manual Operation
Aluminium Construction Pump – Displacement:
1
st
Stage 12.9 cm
3 :
2
nd
Stage 1 cm
maximum working pressure.
HP212, HP232/D, HP252/D – Two Speed Manual
Operation Aluminium Construction Pump –
Displacement: 1
Stage 12.9 cm
st
cm
- 700 bar maximum working pressure
3
HPX1500 – Two Speed Manual Operation Steel
Construction Pump – Displacement: 1
20 cm
2
Stage 1 cm
3 :
nd
3
working pressure
HPX2800 – Two Speed Manual Operation Steel
Construction Pump – Displacement: 1
20 cm
2
Stage 0.8 cm
3 :
nd
working pressure
4.0 Description:
HP110:
The pump may be used either horizontally
1.
or vertically with the hose end downwards.
The pump is equipped with a pressure relief
valve factory set at the maximum
operating pressure. Before use unscrew
Hi-Force Limited – Prospect Way – Daventry – Northants NN11 8PL – United Kingdom
Tel: +44(0) 1327 301000: Fax: +44(0) 1327 706555: Website: www.hi-force.com
INSTRUCTION MANUAL – HYDRAULIC HAND PUMPS:
per
3
st
- 700 bar
3
st
- 700 bar
3
3
- 700 bar
2
Stage 2.3
3 :
nd
Stage
st
- 1500 bar maximum
Stage
st
- 2800 bar maximum
3
transit plug and replace with breather on
the top of the tank. This will maximise the oil
volume available. See Figure 1.
To advance the cylinder, turn the release
2.
knob clockwise. Operate pump handle.
See Figure 2
Note: The cylinder will automatically be
3.
held in the advance position and will not
retract of its own accord.
To retract the cylinder turn release knob
4.
anti-clockwise slowly, ensuring that the
cylinder does not retract too fast as to
make the operation unsafe. See Figure 3.