Hi-Force HPS500 Manual de Instruções - Página 11
Procurar online ou descarregar pdf Manual de Instruções para Sistemas de elevação Hi-Force HPS500. Hi-Force HPS500 14 páginas. Single-acting, low height pad cylinders
Hi-Force tools will use 1 of 2 grades of oil, dependant on the pump used. The tools are designed to operate
at temperatures between -20°C and 80°C. Details of the oil used can be found in the chosen Hi-Force
pump's operating manual, in the section: FILLING THE PUMP WITH OIL.
Hi-Force
Model Number
HFO15
HFO46
Refer to the engraved detail on the cylinder for model identification.
HPS │ SINGLE-ACTING, LOW HEIGHT PAD CYLINDERS
Model
Number
HPS50
HPS51
HPS100
HPS200
HPS300
HPS500
HPS750
HPS1000
HPS1500
8.0 Specifications
8.1 Oil Specifications
ISO Hydraulic Oil Grade
ISO15
ISO46
8.2 HPS Specifications
Capacity
Stroke
(tonnes)
(mm)
4.5
4.5
16
10
10
20
11
32
12
50
15
73
16
109
16
147
16
Operating Instruction Manual:
OM-HPS-01
Temperature Range: Degrees Celcius (°C)
From:
Oil Capacity
3
(cm
)
6
4
10
14
31
55
107
164
245
330
11
Serial Numbers:
From: AF0316
-23
-2
Cylinder eff.
Area
2
(cm
)
6.4
6.4
14.4
28.6
45.6
71.3
102.7
153.4
206.2
To:
44
73
Weight
(kg)
0.8
0.9
1.6
2.6
4.2
6.6
10.4
23.2
28.5