Gaggenau VG 231 AU Manual de instruções de funcionamento e montagem - Página 14

Procurar online ou descarregar pdf Manual de instruções de funcionamento e montagem para Placa de fogão Gaggenau VG 231 AU. Gaggenau VG 231 AU 19 páginas. Gas cooker
Também para Gaggenau VG 231 AU: Instruções de instalação (4 páginas)

Gaggenau VG 231 AU Manual de instruções de funcionamento e montagem

8. Assembly instructions

8.1 Important notes

Please observe the safety notes and the
important notes (Chapter 1).
The installing technician is responsible for
perfect functioning of the appliance at its
installation location. He must explain the operating
principle to the user with reference to the operating
instructions and must show how to switch of the
electricity and gas whenever required.
Caution:
Before connecting the appliance, please check
whether the local connection conditions such as
the gas type, gas pressure and mains voltage and
the appliance settings are correct. Refer to the
adhesive label on the gas connection or the rating
plate for the necessary information. This gas hob
conforms to the categories that are specified on
the rating plate. The rating plate can be found on
the appliance and additionally on the enclosed
addendum sheet. By replacing nozzles, it is
possible to set the appliance to any gas listed on
the rating plate. If the data should not agree, the
appliance must be set to the required gas type and
the available pressure.
As this gas hob is not intended for connection to an
exhaust gas system, pay attention to the applicable
installation conditions.
Note on ventilation:
To ensure good combustion, the room in which this
appliance is installed must have a minimum volume
of 10 m
3
and a door that opens out to outdoors or a
window that can be opened.
VG 231-...
FDxxxx
AC 220-240V
50/60Hz
Qn
5,0 kW
0,8 VA
In Germany, the gas hob must be installed and
connected by a fitter who has been approved by
the gas supply company. At the same time, the
guidelines such as DVGW-TRGI 86 and TRF 1988
and the regulations of the gas supply companies
and of the responsible authorities must be
observed.
In Switzerland, the respectively applicable
regulations of SVGW and of the Association of
Cantonal Fire Insurance Companies as well as the
manufacturer's installation conditions must be
observed when installing the appliance.
In Austria, the ÖVGW-TR Gas (G1) and ÖVGW-TR
Flüssiggas (G2-Part 1) regulations and the local
construction and trade regulations must be
observed when installing the appliance.
The appliance may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures. The
rear wall must consist of non-combustible material.
A minimum distance of 150 mm from heat-sensitive
items of furnishing or contact surfaces (cupboard
side panel) must be observed.
The hob conforms to appliance class 3 and must be
installed in the worktop as shown in the installation
sketch.
The distance between the suspended cupboard
and the worktop must be at least 600 mm. Attention
must be paid to the manufacturer's specified safety
clearance when a vapour extractor is installed. Wall
trims must be heat-resistant, and the minimum
distance between the hob and the wall trim is at
least 35 mm.
After unpacking, check the appliance for any
transportation damage and report this immediately
to the transportation company.
Technical modifications reserved.
13