Daxten VOYAGER IP - Manual do utilizador - Página 12
Procurar online ou descarregar pdf Manual do utilizador para Interruptor Daxten VOYAGER IP -. Daxten VOYAGER IP - 15 páginas.
Troubleshooting - Restoring factory defaults (Hard Reset)
You can restore the factory setting through the Web interface as described on page 7. However if you
cannot access the system e.g. you have forgotten the User Name or Password, you can restore the
factory defaults by performing a Factory Reset.
To perform a Factory Reset:
1. Press and hold down the Go Local button for 3-4 seconds while powering up the Voyager IP.
The device boots up in safe mode.
2. Wait until the unit finishes booting.
3. Login with the default IP address of the unit: http://192.168.0.155/config. (Do not start the
address with https). The Login box appears
4. Type username: admin, password: SAFEmode. (Case sensitive). This username and
password will only work after the reset procedure described above. A menu appears
5. From the menu, choose Restore Factory Settings. A warning appears
6. Select Restore. The factory defaults are restored. When the process finishes
7. Click Reboot to restart the unit
Video resolution and refresh rates
56
Hz
640x480
720x400
800x600
1024x768
1152x864
1152x900
1280x720
1280x768
1280x960
1280x1024
1600x1200
Voyager IP
60
65
66
70
12
72
73
75
User Guide
76
85
86