5.3. Detection range test

The test methods for radar triggering and holding detection range are described separately as
follows.
Trigger range:
The target human body approaches the radar from a distance when no one is reported on the radar,
and stops advancing when the radar starts to report that someone is present, and the current position is
the boundary of the radar trigger detection range; the area enclosed by the detection boundary in each
direction is the radar trigger detection range.
Holding range:
The target human body keeps a small movement in the position to be measured in the state of
radar reported as occupied, such as shrugging shoulders, raising hands, if the radar within 60 s
Always reported as occupied, the current position is within the radar hold detection range;
otherwise, the detection position is outside the hold detection range.
HLK-LD2420
Figure 5-5 Sensing range for wall mounting