If this is not possible, an all-pole isolating switch
▶
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
▶
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
▶
¡ The connection data can be found on the rating
plate inside the appliance.
¡ To see the rating plate, remove the grease filter.
¡ The connecting cable is approx. 1.30 m long.
¡ This appliance complies with the EC interference
suppression regulations.
¡ The appliance corresponds to protection class 1.
Therefore, only use the appliance with a protective
earth connection.
¡ Do not connect the appliance to the power supply
during installation.
¡ Ensure that the protection against contact is guaran-
teed during installation.
12.7 General information
Follow these general instructions during the installation.
¡ For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.
¡ When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.
¡ The width of the extractor hood must correspond at
least with the width of the hob.
¡ To optimally detect the cooking vapours, install the
appliance in the middle of the hob.
¡ In order to freely access the appliance for servicing,
select an easy-to-reach installation site.
¡ The surfaces of the appliance are sensitive. Avoid
damaging them during installation.
12.8 Installation
Checking the unit
Check whether the fitted unit is level and has suffi-
1.
cient load-bearing capacity.
The max. weight of the appliance is 18 kg.
Ensure that the fitted unit is heat-resistant up to
2.
90 °C.
Ensure that the fitted unit is still stable after the cut-
3.
outs have been made.
Ensure that the fitted unit complies with the following
4.
dimensions:
Width
Depth
Position
Wall thickness
600 mm
Min. 320 mm
With lowering frame:
Min. 350 mm
Min. 390 mm
With CleanAir circulat-
ing-air set, min. 600 mm
16 mm or 19 mm
Preparing the units
Requirement: The unit is suitable for the
→ "Checking the unit", Page 13 installation.
Cover the hob to prevent damage.
1.
Ensure that the stability of the fitted unit is guaran-
2.
teed after the cut-outs have been made.
If the cabinet is more than 310 mm deep, remove
3.
part of the back panel.
Create the cut-out for the pipe connection.
4.
If the cabinet base is in place, remove it.
5.
Remove any shavings.
6.
Use the enclosed mounting part to mark the fasten-
7.
ing points on the inside of the cabinet and use a
bradawl to make indentations where the holes are
to be.
19 mm wall thickness: Open up the spacers on
8.
both of the mounting parts.
Installation instructions en
13