Observe the official and statutory
regulations for the removal of exhaust
air (e.g. Landesbauordnungen).
If the extractor hood is operating in
D
exhaust-air mode at the same time as a
flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
there must be an adequate air supply
which the fireplace requires for combusti-
on.
Safe operation is possible if the partial
vacuum in the installation room of the fire-
place does not exceed 4 Pa (0.04 mbar).
This can be achieved if the combustion air
is able to flow through non-lockable ope-
nings, e.g. in doors, windows and in con-
junction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.
If the air supply is inadequate, there is a
risk of poisoning caused by combustion
gases being drawn back into the room.
Note: When assessing the air supply,
always take into account the entire ventila-
tion system in the house. This rule does
not apply when using cooking appliances,
e.g. hob or gas cooker.
Do not attach the outer wall fan near
windows, doors or patios.
When attaching the outer wall fan,
ensure that
– residents and neighbours are not
disturbed by noise and odours,
– it is accessible for maintenance and
repairs.

Prior to installation

The plug-and-socket connections of
the electric cables must be located inside
the building.

Preparing the wall

RISK OF INJURY,
DAMAGE TO PROPERTY
Before drilling the holes for the designated
installation location, check for concealed
electrical cables and other lines.
K The wall must be level and vertical.
K The enclosed screws and wall plugs are
suitable for solid brickwork. Use the
appropriate fixing materials for other wall
structures (e.g. plaster board, porous
concrete, poroton bricks).
Ensure that the wall has adequate load
bearing capacity.
K Ensure that the depth of the drilled holes
corresponds with the length of the scr-
ews.
K Ensure that the wall plugs are secure.
Weight: 7,0 kg.
We reserve the right to construction changes within the
context of technical development.