Section 1. GENERAL DESCRIPTION

The 4110XM is a microprocessor-based state-of-the-art security control intended for wired and wireless
applications. The Control Panel supports up to 14 zones, using basic hard-wired, and/or wireless.
––––––––––––––––––––––––––––––––– FEATURES –––––––––––––––––––––––––––––––––
Zones Supported
6
hardwire
zones,
characteristics:
EOLR supervision supporting N.O. or N.C.
sensors.
300-500 msec normal response.
Zone 3 programmable for Fast Response to
open (10mS).
Up to 8 wireless zones:
Requires the use of a 4281 (5700 System) type
RF receiver as indicated below.
Receiver Model
4281L
4281M
4281H
Requires the use of 5700 series wireless
transmitters.
Detects signals within a nominal range of 200
feet.
––––––––––––––––––––––––––––– SPECIFICATIONS –––––––––––––––––––––––––––––––
4110XM SECURITY CONTROL
1.
Physical: ........................................ 12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x 76mm)
2.
Electrical:
Voltage Input: ................................ 16.5VAC from plug-in 25VA transformer, Ademco No. 1321/TF2 (in U.S.A.),
Rechargeable Back-Up Battery: ... 12VDC, 4AH (Gel type).
Charging Voltage: .......................... 13.8VDC.
Alarm Sounder: ............................. 12V, 2.0 Amp output
Auxiliary Power Output: ............... 12VDC, 500mA max. Interrupts for 4-wire smoke detector reset.
Maximum Zone Resistance: ..... Zones 1-6 = 300 ohms excluding EOLR
Fuse: ................................................ battery (3A) No. 90-12
Line Seize: .................................... Double Pole
3.
Regulatory Information
Ringer Equivalence: ..................... 0.7B
FCC Registration No.: ................... AC 398U-68192-AL-E
UL File No. .................................... S1632, Guide UXOU
U L
In UL installations, maximum current draw from the Auxiliary Output and the Alarm Output
combined must not exceed 600mA total.
having
the
following
No. of Zones
up to 4
up to 8
up to 8
1321CN (in Canada)
Security Codes
1 master code for entire system (user 1)
6 secondary user codes (users 2-7)
Duress code assigned as user 8
Keypad Panic Keys
Provides programmable panic key functions
Activated by wired & wireless keypads
Alarm Output
Provides a 12VDC, 2 AMP output (assumes a fully
charged 4AH battery is connected)
Steady output for Burglary/Panic, or pulsing
output for Fire
Output is current limited
Communication Formats
Ademco Low Speed (Standard or Expanded):
1400Hz ACK/KISSOFF.
Sescoa/Radionics (Standard or Expanded):
2300Hz ACK/KISSOFF.
Ademco Express :
DTMF, 1400/2300Hz ACK, 1400Hz KISSOFF.
Ademco Contact ID:
DTMF 1400/2300Hz ACK, 1400Hz KISSOFF.
-5-