Replacing the injectors
Request change-over injectors from our customer
service deparment (refer injector chart below for sizes).
Natural Gas
Hourly Gas
Consump-
tion (MJ)
Economy
4
burner
Standard-
6.85
output
burner
High-out-
11
put burner
Wok
15
burner
4 kW
1
Remove all pan supports, burner caps and
distributors.
2
To replace the injectors, use the key that is
available from our technical service with code
340847 (for double-flame burners 340808). See
table. It is important to make sure that the injector
does not become detached during removal or
fastening. They must be properly tightened to
ensure that there are no leaks.
With these burners, there is no need to adjust the
primary air.
3
Fasten the distributors and burner caps to the
corresponding burners. In addition to this, put the
pan supports in place on the corresponding
burners.
10
Universal LPG
Injec-
Hourly Gas
Injec-
tor
Consump-
tor
mark
tion (MJ)
mark
88
3.5
50
116
6
66
153
11
87
181
13
98
Adjusting the gas valves
1
Turn the control knobs to the lowest setting.
2
Remove the control knobs from the gas valves. A
flexible rubber sealing ring will be visible. Push
down with the tip of a screwdriver on the gas valve's
setting screw.
Never remove the sealing ring. Sealing rings
prevent liquids and dirt from finding their way into
the appliance and impairing its ability to function
properly.
3
If necessary, use a Torx screwdriver to adjust the
bypass screws:
A: For ULPG the bypass screws must be tightened
properly.
B: For Natural Gas the bypass screws must finish
flush with the fitting.
Make sure that the flame does not go out and that
there are no flashbacks when you turn the control
knob between the highest and lowest setting.
Never remove the gas tap axle. In the event of damage,
the gas valve must be completely replaced.