CEG ECO-MXA 405 Manual de instruções de instalação e funcionamento - Página 7
Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Bomba de água CEG ECO-MXA 405. CEG ECO-MXA 405 20 páginas. Multi-stage water pump with electronic press control
lt is the operator's responsibility to take all preventative measures (e.g. provision of alarm systems, standby pump etc.) To avoid
consequential damages such as flooding due to pump failure.
In order to ensure proper operation a static discharge head of 300mm is required; the discharge pipe must be installed
with a vertical rise of at least 300mm!
Frost damage will not be covered under warranty!
SUCTION GUIDE
Vertical Suction Installation Only
Vertical Suction Pipe
Length (m)
0 - 3m
3 - 6m
6 - 8.5m
9
8
40mm SP
7
6
5
4
3
2
25mm SP
1
Incorrect size selection of pipes may result in pump damage that is not covered under warranty and may affect pump
performance!
ELECTRICAL CONNECTION
The pump should be connected to a separate circuit breaker or fuse with a minimum carrying capacity of 10A. Please note that
if other appliances share an outlet, they may cause low voltage resulting in blown fuses, tripping of motor overload or burning
out of the motor. A permanent earthed connection to the pump is mandatory. ECO-MXA pumps come with an earthing
conductor and a grounding type attachment plug. Do not connect the pump to a power supply until permanently earthed.
For maximum safety, connect pump to a circuit equipped with a Residual Current Device (RCD).
Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may differ slightly from those illustrated and described in this publication.
Horizontal suction pipe length
Minimum Suction
Pipe Diameter (mm)
25mm
32mm
40mm
Table3.0
Suction Pipe Section Chart
Do not operate the pump
in these suction conditions
32mm SP
Horizontal Suction Pipe Length (m)
Vertical suction pipe length
300mm minimum of water above check valve
100mm minimum above bottom
Horizontal Suction Installation Only
Horizontal Suction
Minimum Suction
Pipe Length (m)
Pipe Diameter (mm)
0 - 5m
5 - 10m
10 - 25m
40mm SP
Chart 1.0
Drawing 2.0
25mm
32mm
40mm
Table 3.1
SP = Suction pipe
7