DAYLIFF AQUASTRONG SMART 45 Manual de instalação e funcionamento - Página 6

Procurar online ou descarregar pdf Manual de instalação e funcionamento para Bomba de água DAYLIFF AQUASTRONG SMART 45. DAYLIFF AQUASTRONG SMART 45 16 páginas. Water boosting pump

DAYLIFF AQUASTRONG SMART 45 Manual de instalação e funcionamento

3. INSTALLATION

1
2
3

3.1 Location

The pump can be installed indoors or outdoors but it must not be exposed to
inclement weather. It is recommended that the pump is installed near a drain or in
a drip tray connected to a drain in order to lead away possible condensation from
cold surfaces.

3.2 Minimum Space

The pump requires a minimum space of 620x400x530mm. Even though the
pump does not require much space, it is recommended that there is enough
room for service and maintenance access.

3.3 System Sizing

The pump is factory set with 3bar outlet pressure which can be adjusted
according to demand. The tank pre-charge pressure is 1.25bar.
In case of suction lift of more than 6m, the pump outlet pressure must be at least
2m water column or 0.2bar minimum. Inorder to obtain optimum operation, the
suction lift should be kept as low as possible.
4
5
6
4
1. Pressure Tank
2. Flow Sensor
3. Pressure Sensor
4. Rear Bearing
5. Front Bearing
6. Mechanical Seals