2gig Technologies PASSIVE INFRARED MOTION DETECTOR Instruções de instalação

Procurar online ou descarregar pdf Instruções de instalação para Acessórios 2gig Technologies PASSIVE INFRARED MOTION DETECTOR. 2gig Technologies PASSIVE INFRARED MOTION DETECTOR 2 páginas. Passive infrared motion detector

PASSIVE INFRARED MOTION DETECTOR

FCC ID: WDQ-PIR1345
Industry Canada ID: 7794A-PIR1345
INSTALL INSTRUCTIONS
The Passive Infrared Motion Detector is a wall‐mounted unit with wide 
angle motion protection. When set to High Sensitivity Mode, the Passive 
Infrared Motion Detector (PIR) has a maximum range of 30 feet deep x 50 
feet wide. The PIR is pet immune up to 55 lbs.

Box Contents

Detector
3V Lithium battery
3 screws and 2 dowels
Bracket
Flat wall mount
Corner mount
Programming
The following steps describe general guidelines for programming 
(learning) the PIR into the Control Panel. Scroll between options using the 
← and → arrows. Move to the previous or next prompt by pressing the ↑ 
and ↓ arrows. 
Select RF sensor # (01 to 48). Assign the PIR to a new zone.
1
Select RF sensor type:
2
(04) interior follower
(10) interior with delay
Select RF sensor equipment code. Enter 0533 for the Passive Infrared 
3
Motion Detector.
Select RF equipment type.
4
(2) motion
Enter RF sensor serial number (7 digits).
5
Manual Entry: Type in the last 7 digits of the TX ID that is found 
outside of the box or on the back of the device.
Auto Entry: With the panel in Learn‐in mode, (press Shift then Learn) 
press the tamper switch. The correct TX ID should appear. Accept the 
correct TX ID by pressing ok.
Remember to press the ↓ arrow to continue going through the 
system configuration prompts.
Select RF sensor equipment age (0 to 1).
6
(0) new (product is new)
(1) existing (product already exists)
Select RF sensor loop number (1 to 3).
7
Select RF Sensor dialer delay (0 to 1)
8
(0) disabled
(1) enabled
Construct RF sensor voice descriptor. Press Insert then press any 
9
number between 002 and 255 to add a word. Repeat this for each 
word. For example, if you want to name this PIR as the "master 
bedroom," press Insert then press 140 for master. Press Insert then 
press 024 for bedroom.
Select RF sensor reports (0 to 1).
10
(0) disabled (PIR does not report to the central station)
(1) enabled (PIR reports to the central station)
Select RF sensor supervised (0 to 1)
11
(0) disabled (detector does not report loss of supervision/low battery)
(1) enabled (detector reports loss of supervision/low battery)
Select RF sensor chime (0 to 13).
12
(0) disabled (panel will NOT chime when PIR is activated)
(1‐13) enabled (selects a voice and chime to sound on the panel when 
the PIR is activated)
To program another sensor click next.
13
To exit programming, click skip then end and exit. Upon exit, the 
14
panel takes a several seconds to reboot.
Testing
Before mounting the detector, ensure that the PIR mounting location 
provides good RF communication to the panel. To verify, do the following:
From the Installer Toolbox, select walk test.
1
Place the a magnet over the arrow on the left side of the PIR, (the 
2
detector's LED indicates that a magnet has been detected) and then 
remove the magnet (a magnet is not supplied).
Place the PIR in the location that you plan on mounting it.
3
Move in the area that is to be covered by the PIR and make sure that 
4
the LED on the PIR flashes every time you move. The LED flashing 
continues for 1 minute so you can check the PIR beam coverage.
There is a 3‐second delay between flashes on the LED.
NOTE:
The following can cause a false alarm when testing:
IMPORTANT:
• Leaving the cover off
• Removing jumpers
• Positioning the PIR in direct sunlight or close proximity to a heating or 
an air conditioning duct
Exit installer toolbox.
5
Inserting and Replacing Batteries
If a supervised PIR battery is low, a low battery notification is indicated on 
the Control Panel's touch screen. If indicated, replace the battery 
immediately. Use only the recommended replacement batteries (See 
Specifications).
• Remove back cover by unscrewing bottom screw and pull back cover 
from bottom to top. Observe the polarity of the battery. See Figure 2.
Improper handling of lithium batteries may result in heat 
WARNING:
generation, explosion or fire, resulting in personal injuries. 
Replace only with the same or equivalent type of battery as 
recommended by the manufacturer (see Specifications).
Batteries must not be recharged, disassembled or disposed of in fire. 
Disposal of used batteries must be made in accordance with the 
waste recovery and recycling regulations in your area. Keep Away 
From Small Children. If batteries are swallowed, promptly seek 
medical attention.
California Only: This Perchlorate warning applies only to Manganese 
Dioxide Lithium cells sold or distributed ONLY in /California, U.S.A. 
Perchlorate Material‐special handling may apply. See dtsc.ca.gov/
hazardouswaste/perchlorate.
Installing and Mounting
Remove the screw from the bottom of the case and open the PIR (see 
Figure 1).
Install the 3V Lithium battery from the box.
1
Set the left jumper (PET IMMUNITY) to either 33 lbs. (15 kg) or 55 lbs. 
2
(25 kg; default). (see Figure 2)
Set the right jumper (SENSITIVITY) to either LO (default) or HI (see 
3
Figure 2).
Press and release the tamper switch to begin the power up process.
4
Wait 10 seconds for the PIR to fully power up.
5