WARNING: Improper wiring may result in damage to the
alarm, failure to operate, or a shock hazard. Do not connect white
interconnection wire to L or N.
Wiring mode:
Before connecting the power cord, please pay attention to the label
indication next to the terminal, and then connect to the L, N, and I line
according to the instructions (see Diagram 3).
 L --- Live wire of AC line
 N --- Neutral wire of AC line
 I --- I/O interconnection line
 E ---Earth
W
ARNING:
This product should be installed only by a licensed, qualified
electrician.
Observe and follow all local and national electrical and building
codes for installation.
Isolate from mains power prior to wiring.
Use a minimum of 0.8mm
including signal wire.
Installation:
1. Connect the L, N,
and I lines to the base
3.Align the raised Arrow
markings and clickthe smoke
alarminto the base.
2
250V insulated wire for all wiring,
2.Fix the base on ceiling with
screws and plastic plugs
4. To remove, use a flat
screwdriver to gently lever each
of the three tabsopen.