4. Wire the fan as per fig. C below.
~
L
QF - Circult Breaker
ST - External Switch (e.g. light switch)
5. Amend the timer setting, if desired, following the process on page 6. Replace cover using a
suitable screw driver.
6. On Illuminated versions (32600, 33800, 32700 & 33700) the mains supply should be connected
to the LED driver as per the wiring diagram for lamp (Fig. D).
7. Fix the external grille to the soffit in the same way as the ceiling fascia with 4 screws.
8. For illuminated Cyclone vents, follow the wiring diagram below (Fig. D).

Wiring Diagram For Lamp

(32600, 33800, 32700 & 33700 only)
Live supply is Red or Brown
Neutral supply is Blue or Black
QF
AC in
N
L
ST
LT
Do Not Use
LI
DC out
(Fig. C)
Live is Red
Neutral is Black
(Fig. D)
5
hib.co.uk