HIBLOW HP Series Manual - Página 5

Procurar online ou descarregar pdf Manual para Bombas para lagos HIBLOW HP Series. HIBLOW HP Series 8 páginas.
Também para HIBLOW HP Series: Manual (5 páginas), Manual (9 páginas), Manual de início rápido (7 páginas)

HIBLOW HP Series Manual
HP- 150 / 200
STEP
STEP
12
12
Insert the actuating rod into the machine body. Be 
sure  to  fit  the  positioning  boss  on  the  diaphragm 
base into the concave part of the frame stay. 
Secure  the  diaphragm  mounting  block  on  the 
other  side  and  tighten  washers  and  U-lock  nuts 
with the nut driver. 
Make  sure  that  gap  between  the  actuating  rod 
and the electromagnets is even.
STEP
STEP
13
13
Mount the casing block with screws (4 screws on 
each side). 
And  insert  L-tube  into  the  nozzle  of  casing  A. 
Then, fix it with hose clip. 
Complete the other casing block in the same way.
STEP
STEP
REPLACEMENT OF SAFETY PIN
14
14
Check that the broken pin is removed from unit. 
●If the broken pin is left inside the unit, it can get caught 
in  between  electromagnets  and  actuating  rod,  which 
can cause breakdown.
STEP
STEP
15
15
Insert  a  new  safety  pin  through  the  hole  on  the 
terminal side. 
(Please  Insert  safety  pin  through  the  spring 
electrode, L-shaped lever in such order.)
REPLACING THE CHAMBER BLOCK
5