HIBLOW hp-200 Manual - Página 5
Procurar online ou descarregar pdf Manual para Bombas para lagos HIBLOW hp-200. HIBLOW hp-200 8 páginas. Air pumps
Também para HIBLOW hp-200: Manual de instruções (13 páginas), Manual de instruções (17 páginas)
HP- 150 / 200
STEP
STEP
12
12
Insert the actuating rod into the machine body. Be
sure to fit the positioning boss on the diaphragm
base into the concave part of the frame stay.
Secure the diaphragm mounting block on the
other side and tighten washers and U-lock nuts
with the nut driver.
Make sure that gap between the actuating rod
and the electromagnets is even.
STEP
STEP
13
13
Mount the casing block with screws (4 screws on
each side).
And insert L-tube into the nozzle of casing A.
Then, fix it with hose clip.
Complete the other casing block in the same way.
STEP
STEP
REPLACEMENT OF SAFETY PIN
14
14
Check that the broken pin is removed from unit.
●If the broken pin is left inside the unit, it can get caught
in between electromagnets and actuating rod, which
can cause breakdown.
STEP
STEP
15
15
Insert a new safety pin through the hole on the
terminal side.
(Please Insert safety pin through the spring
electrode, L-shaped lever in such order.)
REPLACING THE CHAMBER BLOCK
5