HIBLOW hp-150 Manual - Página 8

Procurar online ou descarregar pdf Manual para Bomba de água HIBLOW hp-150. HIBLOW hp-150 8 páginas. Air pumps
Também para HIBLOW hp-150: Manual de instruções (13 páginas), Manual de instruções (17 páginas)

HIBLOW hp-150 Manual
HP- 150 / 200
STEP
STEP
MOUNTING THE ELECTROMAGNET
4
4
Mount new electromagnet in the unit. 
Fix frame stay temporarily. 
(Do  not  tighten  screw  of  frame  stay  and  keep 
them rather loose.) 
Tighten up hexagonal nuts with nut driver. 
Fasten screws of frame stay.
STEP
STEP
5
5
Install the SP switch to the frame with the screws.
●Be careful of the direction of switch lever. (Refer to the 
pictures)
STEP
STEP
6
6
Insert the wire into the silicon tube, and tie up in a 
bundle. 
Strip the coating off each wire. 
(5-7mm from the end) 
Connect the wires to the terminals. 
Solder the wires to the terminals. 
The wire requires a soldered connection.
STEP
STEP
7
7
This  completes  the  electromagnet  replacement 
procedure.
8
REPLACING THE ELECTROMAGNET