(4) Loosen the U-lock nut and remove one of diaphragm mounting blocks from the rod, and pull out
the other diaphragm mounting block from the pump body together with the rod without loosening
its U-lock nut. (Figs. 7 and 8)
• Since we use powerful permanent magnets for the rod, take care not to get your fingers pinched
by unexpectedly being attracted with its force.
• When pulling out the rod, take care not to allow the rod projection to accidentally to hit the lever of
the automatic stop switch, as this may result in the safety screw of the switch damaging or in its
malfunction.
���� �
(5) To replace the diaphragm of the removed diaphragm mounting block, with a new one, first
remove the diaphragm ring from the diaphragm, then the diaphragm from the diaphragm base.
The ring and the diaphragm can be easily removed by hand, and if it is difficult to do so, then
hold them using radio pliers or the like, and pull them out one by one. (Figs. 9 and 10)
Fig. 9
8
��������� �������� �����
Diaphragm base
Diaphragm
Diaphragm ring
CAUTION
���� �
��������� �������� �����
������
������ ���
Fig. 10
���
Diaphragm base
Diaphragm