GAI-Tronics 12576-502 Manual do utilizador - Página 5

Procurar online ou descarregar pdf Manual do utilizador para Telefone GAI-Tronics 12576-502. GAI-Tronics 12576-502 13 páginas. Desktop access panels

GAI-Tronics 12576-502 Manual do utilizador
Pub. 42004-732L2C
Model 12576-502 & 12576-50215 Desktop Access Panels
Page 5 of 11

Settings and Adjustments

User Adjustments

Speaker Volume Adjustment
The speaker volume control on the rear of the unit adjusts the volume level of the internal speaker.
Clockwise rotation will increase the volume and counterclockwise rotation will decrease the volume.
: The handset must be on-hook to adjust the speaker volume because the speaker is muted when the
N
OTE
handset is off-hook.
Sonalert Volume Adjustment
The sonalert volume control on the rear of the unit adjusts the volume level of the sonalert (sounder).
Clockwise rotation will increase the volume and counterclockwise rotation will decrease the volume.

Internal Adjustments

Opening the Enclosure
Carefully flip over the unit. Remove the four screws from the bottom of the plastic enclosure. Open the
access panel by removing the bottom enclosure to the right of the unit. Be careful not to disconnect any
cables.
Jumper Settings
External Audio Input
Jumper P6 on No. 69447-xxx PCBA must be set to match the input level of the external audio source
connected to the audio accessory port. Place P6 in the HI position (default setting) for a line level
(0.775 Vrms) audio signal. Place P6 in the LO position for microphone level (3 mVrms) audio signals.
Refer to Figure 6 for jumper location.
TX/RX Data
Jumper P9 on No. 69447-xxx PCBA provides a ground reference to the access panel data line. A similar
jumper is located on the Access Panel Interface (API) card in the system control cabinet. The data line
must be ground referenced on one side of the communication link but not both. Place P9 in the GND
position to create a ground reference. Place P9 in the FLOAT position (default) to remove the ground
reference. Refer to Figure 6 for jumper location.
e:\standard ioms - current release\42004 instr. manuals\42004-732l2c.doc
07/14