Hickok FPT2600-EX1 Manual do utilizador - Página 10

Procurar online ou descarregar pdf Manual do utilizador para Equipamento de teste Hickok FPT2600-EX1. Hickok FPT2600-EX1 16 páginas. I/m handheld fuel cap test system

Connecting & Using the Tester
Before You Begin
• Please read the instructions carefully before using the tester. Failure
to follow the instructions may cause incorrect test results.
• Before using the tester for the first time, remove the battery
protector pull tab.
• Make sure the vehicle is turned off before removing the fuel cap.
• When removing the fuel cap, do so slowly and allow any pressure to
decay before fully removing the cap.
• Because residual pressure from a previous test will cause an
incorrect auto zero, never power up the tester with the fuel cap
connected to the adapter.
Step 1—Check the Tester's Flow Rate Calibration
Always check the tester's flow rate calibration before initial use for
certified vehicle testing and before testing begins each day. Failure to
check the tester's calibration may cause inaccurate test results. There are
two parts to this test—one with the swing valve set to Pass, and the other
with the valve set to Fail.
• Do not attach the Pass/Fail Standard to the tester until after the
power is on.
• Install the Pass/Fail Standard and start the test as soon as possible
after auto zero.
If testing is not started within one minute after auto zero, the tester
will shut itself off. If this happens, repeat the instructions for the
calibration test from the beginning.
• Do not disturb (turn or press) the Pass/Fail Standard during pumping
and testing.
IMPORTANT! If the Flow Rate Calibration Check fails, do not use the
tester for certified testing. Contact Waekon Customer Service for
technical assistance.
10 FPT2600-EX1 User Guide